Device Problem
Adverse Event Without Identified Device or Use Problem (2993)
|
Patient Problems
Bone Fracture(s) (1870); Granuloma (1876); Neuropathy (1983); Post Operative Wound Infection (2446); Muscle/Tendon Damage (4532)
|
Event Type
Injury
|
Manufacturer Narrative
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.This report is for an unknown elastic nails: titanium/unknown lot.Part and lot numbers are unknown; udi number is unknown.Complainant part is not expected to be returned for manufacturer review/investigation.Without a lot number the device history records review could not be completed.Product was not returned.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial, a follow-up will be filed as appropriate.
|
|
Event Description
|
Device report from synthes reports an event in germany as follows: this report is being filed after the review of the following journal article: lieber, j.Et.Al.(2021).Implant removal associated complications after esin osteosynthesis in pediatric fractures., european journal of trauma and emergency surgery, vol.48 (xx) pages 3471-3478., (germany).The aim of this retrospective data analysis was to analyze the incidence and type of complications that occurred during or after the removal of ten (titanium elastic nails) in children.Between january 2004 and december 2013, a total of 432 patients [ 287 males and 145 females with mean age of 7.2 years (1¿15)] underwent esin (elastic stable intramedullary nailing) osteosynthesis within the 10-year period.Tens were implanted in such a manner (nail ends were situated outside the cortical bone and above tendons or fascias) that planned removal surgery after bone remodeling would be a minimal intervention.The median clinical follow-up period was unknown.The following complications were reported as follows: rupture of the tendon of the m.Extensor pollicis brevis.The injury was recognized intraoperatively, and the reconstruction was performed during the same anesthesia with subsequent immobilization in a plaster splint for 3 weeks.After mobilization, no restriction of movement was found at last presentation.In 1 patient, a refracture at the forearm occurred, however, remodeling prior to ten removal was completed.10 minor complications were temporary or without irreversible restrictions: superficial/deep infections (n = 3), hypertrophic scarring and/or granuloma formation (n = 5), and temporary paraesthesia/hyposensibility at the thumb as a sign of damage to the superficial radial nerve (n = 2).This report involves one unk - elastic nails: titanium.This is report 1 of 1 for (b)(4).
|
|
Event Description
|
This report involves one unk - constructs: titanium elastic nail.
|
|
Search Alerts/Recalls
|
|
|