Model Number 00-1024-R
Device Problems Unable to Obtain Readings (1516); Detachment of Device or Device Component (2907)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 12/29/2022
Event Type  malfunction  
Event Description
The customer reported ekg failed to function correctly and attempted to change leads and electrodes with no luck.A user report was received related to a reported product problem which is currently being investigated.Further updates will be provided when the investigation is in progress.
 
Manufacturer Narrative
Philips received a complaint on the tempus pro indicating that ecg does not function.Customer swapped leads and electrodes with no improvement.The complaint was escalated for technical investigation and the results indicate the ecg flex nut came lose allowing the ecg flex cable to be pulled from the ecg board.The ecg flex nut was tightened and the ecg flex cable was able to be secured correctly to the ecg board.Device has been soaked for 48 hours to ensure issue had been corrected.No parts were required for a repair.Nbp, co2 and touch screen have been calibrated.The unit was returned to the customer site.A review of the risk management file was performed, and the potential severity is s2 has been identified in the risk document.The data entered in this complaint record will be utilized for product quality and safety improvements per the post market surveillance and risk management processes.The device was operational after repairs were completed.It has been concluded that no further action is required at this time.If additional information is received the complaint file will be reopened.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TEMPUS PRO
Type of Device
MONITOR, PHYSIOLOGICAL, PATIENT (WITH ARRHYTHMIA DETECTION OR ALARMS)
Manufacturer (Section D)
REMOTE DIAGNOSTIC TECHNOLOGIES LTD.
ascent 1, aerospace centre
aerospace boulevard
farnborough GU14 6XW
UK  GU14 6XW
Manufacturer (Section G)
REMOTE DIAGNOSTIC TECHNOLOGIES LTD.
ascent 1, aerospace centre
aerospace boulevard
farnborough GU14 6XW
UK   GU14 6XW
Manufacturer Contact
tanya deschmidt
ascent 1, aerospace centre
aerospace boulevard
farnborough GU14 -6XW
UK   GU14 6XW
MDR Report Key16252956
MDR Text Key308383121
Report Number3003832357-2023-00021
Device Sequence Number1
Product Code MHX
UDI-Device Identifier05060472441027
UDI-Public05060472441027
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K201746
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type User Facility
Reporter Occupation Other
Type of Report Initial,Followup
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number00-1024-R
Device Catalogue Number989706000051
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 12/29/2022
Initial Date FDA Received01/27/2023
Supplement Dates Manufacturer Received12/29/2022
Supplement Dates FDA Received10/27/2023
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
Patient Outcome(s) Other;
-
-