• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ABBOTT VASCULAR PRESSUREWIRE¿ X GUIDEWIRE; CATHETER TIP PRESSURE TRANSDUCER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ABBOTT VASCULAR PRESSUREWIRE¿ X GUIDEWIRE; CATHETER TIP PRESSURE TRANSDUCER Back to Search Results
Model Number X
Device Problems Break (1069); Stretched (1601)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 01/10/2023
Event Type  malfunction  
Manufacturer Narrative
The device is expected to be returned for investigation.It has not yet been received.A follow-up report will be submitted with all additional relevant information.
 
Event Description
It was reported the pressurewire x (pwx) wireless connected and equalized successfully.When the pwx was in the distal left anterior descending artery, it was noted that the tip was frayed and stretched out.The core separated but the guide wire was held together by tip coils a new pwx was used to complete the procedure.There were no adverse patient effects and no clinically significant delay during the procedure.No additional information was provided.
 
Manufacturer Narrative
Visual analysis was performed on the returned device.The reported break was not confirmed there was no core separation as reported.The reported stretch was confirmed as the distal coils were found to be stretched 1mm proximal to the distal tip.The core was bent 1mm distal to the sensor.There were multiple bends throughout the proximal wire core.A review of the lot history record identified no manufacturing nonconformities issued to the reported lot that would have contributed to this event.Additionally, a review of the complaint history identified no other similar complaints reported from this lot.Based on the information received and analysis of the returned device, the investigation determined that the reported stretch was due to circumstances of the procedure.It is likely that, during device preparation, the device was inadvertently stretched at the distal end.Additionally, a break could not be confirmed and was not observed during the returned analysis.There is no indication of a product quality issue with respect to the design, manufacture, or labeling of the device.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PRESSUREWIRE¿ X GUIDEWIRE
Type of Device
CATHETER TIP PRESSURE TRANSDUCER
Manufacturer (Section D)
ABBOTT VASCULAR
26531 ynez rd.
temecula CA 92591 4628
Manufacturer (Section G)
ABBOTT VASCULAR COSTA RICA, REG # 3009564766
52 calle 3 b31 coyol free zone
el coyol alajuela
CS  
Manufacturer Contact
lindsey bell
26531 ynez rd.
temecula, CA 92591-4628
9519143996
MDR Report Key16265186
MDR Text Key308390287
Report Number2024168-2023-00946
Device Sequence Number1
Product Code DXO
UDI-Device Identifier05415067025715
UDI-Public05415067025715
Combination Product (y/n)N
Reporter Country CodeBE
PMA/PMN Number
K180558
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 03/16/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date05/31/2024
Device Model NumberX
Device Catalogue NumberC12059
Device Lot Number20621G1
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 01/13/2023
Initial Date FDA Received01/30/2023
Supplement Dates Manufacturer Received03/10/2023
Supplement Dates FDA Received03/16/2023
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured06/21/2022
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-