Model Number ASKU
Device Problems Crack (1135); Failure to Advance (2524)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 01/25/2023
Event Type  malfunction  
Event Description
A nurse reported that during intraocular lens (iol) implant procedure, the lens could not be advanced, it was pushed out and reloaded in a new cartridge to complete the surgery.After surgery, when inspecting, a crack on cartridge was noticed.There was no patient harm.
 
Manufacturer Narrative
A sample device was not returned for analysis.Complaint history and product history record could not be reviewed because the reporting facility did not provide a valid lot number or any identification traceable to the manufacturing documentation.Root cause has not been identified.A photo was provided of video monitor.The lower part of a cartridge nozzle and the tip are visible on the screen.The nozzle has a v-shaped crack on the top which splits as it enters the thinner tip.Unable to determined other viscoelastic device (ovd) from the photo.The manufacturer internal reference number is:(b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MONARCH IOL DELIVERY SYSTEM, CARTRIDGE
Type of Device
FOLDERS AND INJECTORS, INTRAOCULAR LENS (IOL)
Manufacturer (Section D)
ALCON RESEARCH, LLC - HUNTINGTON
6065 kyle lane
huntington WV 25702
Manufacturer (Section G)
ALCON RESEARCH, LLC - HUNTINGTON
6065 kyle lane
huntington WV 25702
Manufacturer Contact
jonathan schlech
6201 south freeway
mail stop ab2-6
fort worth, TX 76134
8007579780
MDR Report Key16370173
MDR Text Key309594825
Report Number1119421-2023-00314
Device Sequence Number1
Product Code MSS
Combination Product (y/n)N
Reporter Country CodeCA
PMA/PMN Number
P063155
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional
Reporter Occupation Nurse
Type of Report Initial
Report Date 02/14/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberASKU
Device Catalogue NumberASKU
Device Lot NumberASKU
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 01/30/2023
Initial Date FDA Received02/14/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Treatment
ACRYSOF ASPHERIC UV ABSORBING SINGLEPIECE IOL; MONARCH II LOADING FORCEPS; MONARCH III IOL DELIVERY SYSTEM, INJECTOR; PROVISC OPHTHALMIC VISCOSURGICAL DEVICE
-
-