WRIGHT MEDICAL TECHNOLOGY INC UNKNOWN INBONE TIBIAL COMPONENT; PROSTHESIS, ANKLE, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER Back to Search Results
Catalog Number UNK_WWA
Device Problems Insufficient Information (3190); Migration (4003)
Patient Problems Cyst(s) (1800); Ankylosis (4527); Insufficient Information (4580)
Event Date 01/25/2023
Event Type  Injury  
Manufacturer Narrative
The device is not available for evaluation as it remains implanted in the patient.A review of the device history is not possible because the lot number was not communicated.If additional information becomes available, it will be provided on a supplemental report.Device remains implanted in patient.
 
Event Description
It was reported that the patient underwent a total ankle replacement.Allegedly, the patient may need to undergo a revision surgery for reasons that are not available at the time of this report.
 
Manufacturer Narrative
The reported event could be confirmed, since images of ct scans were provided and shows signs of loosening around the tibial and talar components.A medical professional reviewed the received information and noted the following: ¿the tibial component shows some smaller cysts and cavities, a little radiolucence around the implant suggesting loosening.The reported ankyloses in the adjacent joints can be confirmed.The pe is not directly visible, but there are no clear signs of breakage or dislocation.The talar component shows the same signs of loosening as the tibial part, however, the bone stock here is explicitly poor with cysts, cavities all around the bone proving a bone metabolic disorder.¿ based on investigation, the root cause was attributed to a patient related issue.The failure was most likely caused by poor bone quality.A review of the device history was not possible because the lot number was not communicated.No corrective actions are required at this time.A review of the labeling did not indicate any abnormalities.Indications of material, manufacturing, or design related problems were unable to be identified as the catalog number and lot number were not communicated.If the device is returned or if any additional information is provided, the investigation will be reassessed.
 
Event Description
It was reported that the patient underwent a total ankle replacement.Allegedly, the patient may need to undergo a revision surgery for reasons that are not available at the time of this report.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNKNOWN INBONE TIBIAL COMPONENT
Type of Device
PROSTHESIS, ANKLE, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER
Manufacturer (Section D)
WRIGHT MEDICAL TECHNOLOGY INC
1023 cherry rd
memphis TN 38117
Manufacturer (Section G)
WRIGHT MEDICAL TECHNOLOGY, INC.
11576 memphis arlington rd
arlington TN 38002
Manufacturer Contact
anna jusinski
325 corporate drive
mahwah, NJ 07430
2018315000
MDR Report Key16405947
MDR Text Key309858724
Report Number3010667733-2023-00076
Device Sequence Number1
Product Code HSN
Combination Product (y/n)N
Reporter Country CodeUS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 05/05/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Lay User/Patient
Device Catalogue NumberUNK_WWA
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 01/25/2023
Initial Date FDA Received02/20/2023
Supplement Dates Manufacturer Received04/10/2023
Supplement Dates FDA Received05/09/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other;