• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: DRÄGERWERK AG & CO. KGAA FABIUS TIRO; ANESTHESIA UNITS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

DRÄGERWERK AG & CO. KGAA FABIUS TIRO; ANESTHESIA UNITS Back to Search Results
Catalog Number 8606000
Device Problems Gas Output Problem (1266); Failure to Deliver (2338); Protective Measures Problem (3015)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 02/27/2023
Event Type  malfunction  
Manufacturer Narrative
The investigation has just started; results will be provided in a follow-up report.
 
Event Description
It was reported that the unit stopped working during a case.There was no injury reported.
 
Event Description
It was reported that the unit stopped working during a case.There was no injury reported.
 
Manufacturer Narrative
The log file was available for investigation.On the reported date of event no entries are logged.But, some days before several entries are listed indicating vent fails, as reported.The device disabled automatic ventilation as a safety measure against a too high measured airway pressure and alarmed for ventilator fail !!!.In case the airway pressure recovers, the device continues automatic ventilation on its own.Due to limited information no root cause could be determined.As the issue could not be reproduced, an external impact is likely, as coughing by the patient or repositioning of patient.No hint for a device malfunction was found.In case automatic ventilation is shut down, manual ventilation and monitoring functions remain available.Restrictive issues will be detected during self test before use.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FABIUS TIRO
Type of Device
ANESTHESIA UNITS
Manufacturer (Section D)
DRÄGERWERK AG & CO. KGAA
moislinger allee 53-55
lübeck
GM 
Manufacturer (Section G)
DRÄGERWERK AG & CO. KGAA
moislinger allee 53-55
lübeck 23542
GM   23542
Manufacturer Contact
moislinger allee 53-55
lübeck 23542
4518822868
MDR Report Key16544777
MDR Text Key311422117
Report Number9611500-2023-00096
Device Sequence Number1
Product Code BSZ
UDI-Device Identifier04048675041474
UDI-Public(01)04048675041474(11)201223(17)210407(93)8606000-89
Combination Product (y/n)N
PMA/PMN Number
K042419
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type User Facility,Company Representative
Reporter Occupation Biomedical Engineer
Type of Report Initial,Followup
Report Date 10/26/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number8606000
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 03/03/2023
Initial Date FDA Received03/15/2023
Supplement Dates Manufacturer Received10/23/2023
Supplement Dates FDA Received10/26/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured12/31/2020
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-