• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BOSTON SCIENTIFIC DE COSTA RICA S.R.L. POLARMAP; CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC DE COSTA RICA S.R.L. POLARMAP; CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING Back to Search Results
Lot Number 0030513992
Device Problem Material Perforation (2205)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 01/16/2023
Event Type  malfunction  
Manufacturer Narrative
The polarmap catheter was returned to boston scientific for laboratory analysis.A visual inspection was performed, and the catheter failed.Upon device return it was observed that the catheter was kinked with a cut in the insulation at the location of the kink.Laboratory analysis was able to confirm the reported clinical observation.
 
Event Description
Reportable based on analysis completed on 17 february 2023.During a catheter ablation procedure to treat atrial fibrillation (a fib) a polarmap catheter was selected for use.The catheter shaft was found to be kinked while the product was being prepared.The catheter was exchanged for another of the same model.The procedure was completed with no patient complications.The catheter was received and analyzed by boston scientific's post market laboratory.The visual inspection identified an insulation cut.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
POLARMAP
Type of Device
CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING
Manufacturer (Section D)
BOSTON SCIENTIFIC DE COSTA RICA S.R.L.
302 parkway
global park, la aurora
heredia
CS 
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
302 parkway, global park
la aurora - heredia
CS  
Manufacturer Contact
timothy degroot
4100 hamline avenue north
dc a330
saint paul, MN 55112
6515826168
MDR Report Key16550160
MDR Text Key311387899
Report Number2124215-2023-10461
Device Sequence Number1
Product Code DRF
Combination Product (y/n)N
Reporter Country CodeJA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial
Report Date 03/15/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date11/09/2023
Device Lot Number0030513992
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/02/2023
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 02/17/2023
Initial Date FDA Received03/15/2023
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured11/09/2022
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-