MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION SPYSCOPE DS II ACCESS & DELIVERY CATHETER; CHOLEDOCHOSCOPE AND ACCESSORIES, FLEXIBLE/RIGID

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION SPYSCOPE DS II ACCESS & DELIVERY CATHETER; CHOLEDOCHOSCOPE AND ACCESSORIES, FLEXIBLE/RIGID Back to Search Results
Model Number M00546610
Device Problems Poor Quality Image (1408); Device-Device Incompatibility (2919); Difficult to Advance (2920); Optical Problem (3001)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 02/21/2023
Event Type  malfunction  
Event Description
It was reported to boston scientific corporation that a spyscope ds ii access & delivery catheter was used in the pancreatic duct during an endoscopic retrograde cholangeopancreatography (ercp) and electrohydraulic lithotripsy (ehl) procedure performed on (b)(6) 2023.During the procedure, the image of the spyscope ds ii was lost about two hours of usage.Initially, the ehl probe would not cross and became stuck around the tip of the spyscope ds ii.The image became distorted and eventually lost.The procedure was not completed and reschedule to the next session as the procedure time was prolonged.There were no patient complications reported as a result of this event.
 
Manufacturer Narrative
Imdrf impact code f1001 is being used to capture the reportable event of aborted/cancelled procedure.
 
Event Description
It was reported to boston scientific corporation that a spyscope ds ii access & delivery catheter was used in the pancreatic duct during an endoscopic retrograde cholangeopancreatography (ercp) and electrohydraulic lithotripsy (ehl) procedure performed on (b)(6) 2023.During the procedure, the image of the spyscope ds ii was lost about two hours of usage.Initially, the ehl probe would not cross and became stuck around the tip of the spyscope ds ii.The image became distorted and eventually lost.The procedure was not completed and reschedule to the next session as the procedure time was prolonged.There were no patient complications reported as a result of this event.
 
Manufacturer Narrative
Block h6 (impact codes): imdrf impact code f1001 is being used to capture the reportable event of aborted/cancelled procedure.Block h10: the returned spyscope ds ii was analyzed, and a visual evaluation noted signs of use in the form elevator marks on the shaft of the catheter.Elevator marks were measured approximately from the tip and no damage was noted.Witness marks were observed on the contacts of the umbilicus connector, indicating it was connected to a controller.An image assessment for visualization was performed.The device was plugged into the controller.A live, clear image was displayed.No problems were observed with physical connectivity of the device.The umbilicus connector was visually inspected, and no damage or defects were noted.The device was fully articulated in all directions; no problems were identified with the image.X-ray imaging of the distal tip showed no problems with the redistribution layer (rdl) or thru-silicon vias (tsvs).X-ray imaging of the handle showed no problems with the printed circuit board assembly (pcba) or camera wires.A functional assessment of accessory passability was performed.Testing was conducted with an autolith ehl probe.First, the spyscope was introduced into an articulation fixture to test for passability.No problems were observed and the spyscope passed freely.The ehl probe was passed through the spyscope in a straight configuration and no difficulty was observed.The probe passed freely.The probe was removed from the device with no problem observed.The spyscope device was placed in an articulation fixture and a functional assessment was repeated by passing the probe through the device.The probe passed freely.The probe was removed from the device with no problem observed.The handle was opened and the components within were visually inspected.It was noted that there was procedural residue on the plastic optical fibers (pofs) and camera wire in the breakout region, indicated procedural fluids had flowed back up the optics lumen into the handle during use.The tip was blocked, and saline was flushed through the irrigation tubing to induce backflow of saline into the optics lumen.This caused the image to be disrupted, with blue and orange lines across the screen and a purple hue, leading to a full loss of image.The saline was drained from the optics lumen and the image was restored.The reported event was confirmed.During product analysis, it was noted that procedural residue remained at the top of the optics lumen in the breakout.The optics lumen was filled with saline and the image was disrupted.Draining the optics lumen resulted in the restoration of the image.The image signal does not withstand the change in capacitance created by the introduction of saline into the optics lumen, and procedural factors can cause this fluid to enter the optics lumen during use.An investigation to address this problem has been completed.Based on all gathered information, the probable cause selected for the image failure due to fluid in the optics lumen is cause traced to device design, which indicates that the problems are traced to the design specifications.A labeling review was performed and, from the information available, this device was used per the instructions for use (ifu) / product label.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SPYSCOPE DS II ACCESS & DELIVERY CATHETER
Type of Device
CHOLEDOCHOSCOPE AND ACCESSORIES, FLEXIBLE/RIGID
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
780 brookside drive
spencer IN 47460
Manufacturer Contact
carole morley
300 boston scientific way
marlborough, MA 01752
5086834015
MDR Report Key16582725
MDR Text Key312044179
Report Number3005099803-2023-01298
Device Sequence Number1
Product Code FBN
UDI-Device Identifier08714729965404
UDI-Public08714729965404
Combination Product (y/n)N
Reporter Country CodeJA
PMA/PMN Number
K183636
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Foreign,Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 04/26/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberM00546610
Device Catalogue Number4661
Device Lot Number0029736189
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 02/21/2023
Initial Date FDA Received03/21/2023
Supplement Dates Manufacturer Received03/28/2023
Supplement Dates FDA Received04/26/2023
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured07/11/2022
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-