Model Number 7700FB30 |
Device Problem
Adverse Event Without Identified Device or Use Problem (2993)
|
Patient Problems
Stroke/CVA (1770); Muscle Weakness (1967); Blurred Vision (2137)
|
Event Date 06/23/2022 |
Event Type
Injury
|
Manufacturer Narrative
|
Product analysis: the device remains implanted, therefore no product analysis can be performed.Conclusion: without the return of the product, no definitive conclusion can be made regarding the clinical observation.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
|
Event Description
|
Medtronic received information that 1 month post implant of this 30mm mitral annuloplasty band, it was reported that the patient had symptoms of worsening visual field deficits, confabulation and left sided weakness.A magnetic resonance imaging (mri) discovered numerous acute, subacute and areas of susceptibility enhancement, including remote left frontal infarction.One day later, a computerized tomography (ct) scan discovered evolving territorial hypointensity in the bilateral parieto-occipital regions, likely representing evolving infarctions.That same day, an echocardiogram (echo) discovered minimally thickened mitral valve leaflets with a mean gradient of 6mmhg.Anticoagulation medications were continued.No additional adverse patient effects were reported.
|
|
Manufacturer Narrative
|
Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
|
Event Description
|
Medtronic received information that 1 month post implant of this 30mm mitral annuloplasty band, a magnetic resonance imaging (mri) discovered numerous acute and subacute infarcts, areas of susceptibility enhancement, including remote left frontal infarction.One day later, it was reported that the patient had symptoms of a stroke which included worsening visual field deficits, confabulation and left sided weakness.A computerized tomography (ct) scan discovered evolving territorial hypointensity in the bilateral parieto-occipital regions, likely representing evolving infarctions.That same day, an echocardiogram (echo) discovered minimally thickened mitral valve leaflets with a mean gradient of 6mmhg.Anticoagulation medications were continued.No additional adverse patient effects were reported.
|
|
Event Description
|
Additional information was received that reported a second mri discovered chronic post ischemic changes in the left basal ganglia which were reported as new findings compared to the prior mri done one day before, however they found this to be stable.The patient has since recovered/resolved.No additional adverse patient effects were reported.
|
|
Manufacturer Narrative
|
Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
|