Model Number 866389
Device Problem Application Network Problem (2879)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 05/09/2023
Event Type  malfunction  
Manufacturer Narrative
A follow-up report will be submitted upon completion of the investigation.
 
Event Description
The customer reported that they lost network connection on all floors.The device was in clinical use at the time the issue was discovered.There was no adverse event or patient harm reported.
 
Manufacturer Narrative
A philips technical consultant (tc) went to the customer site.The mobility server wymc07103 was showing to be offline, and testing was performed.Results of functional testing indicate it was a virtual server that went down.The owner rebuilt its virtual server and was run it through setup and restored to service.This was noted to by a hybrid system; the network in the hospital is a philips supplied clinical network (pscn), while the virtual server is on a customer supplied clinical network (cscn).Based on the information available and the testing conducted, the problem was confirmed; the cause of the reported problem was the customer¿s virtual server.The device was operational after repairs were completed.The investigation concludes that no further action was required at this time.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PATIENT INFORMATION CENTER IX
Type of Device
PATIENT INFORMATION CENTER IX
Manufacturer (Section D)
PHILIPS MEDICAL SYSTEMS
3000 minuteman rd
andover MA 01810
Manufacturer (Section G)
PHILIPS MEDICAL SYSTEMS
3000 minuteman rd
andover MA 01810
Manufacturer Contact
hisham alzayat
3000 minuteman rd
andover, MA 01810
6172455900
MDR Report Key16974786
MDR Text Key315866258
Report Number1218950-2023-00339
Device Sequence Number1
Product Code MHX
UDI-Device Identifier00884838093041
UDI-Public00884838093041
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K153702
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional,User Facility,Company Representative
Reporter Occupation Biomedical Engineer
Type of Report Initial,Followup
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number866389
Device Catalogue Number866389
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 05/09/2023
Initial Date FDA Received05/22/2023
Supplement Dates Manufacturer Received05/09/2023
Supplement Dates FDA Received05/30/2023
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured07/15/2020
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-