PROCEPT BIOROBOTICS CORPORATION AQUABEAM ROBOTIC SYSTEM; FLUID JET REMOVAL SYSTEM Back to Search Results
Model Number AB2000
Device Problem Infusion or Flow Problem (2964)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 06/15/2023
Event Type  malfunction  
Manufacturer Narrative
Root cause of reported event has not yet been established.Investigation by manufacturer is currently in-process.Submission of this report does not constitute an admission that the manufacturer's product caused or contributed to the event.
 
Event Description
A male patient with symptomatic benign prostatic hyperplasia (bph) received an aquablation procedure.Procept biorobotics corporation (procept) became aware that during the alignment phase, the aquabeam handpiece (hp) waterjet exhibited irregular jetting and the aquabeam cpu screen would intermittently freeze.While the jet worked as intended during the priming, the surgeon felt that the hp and trus were inadequately rotated based on the patient's positioning on the bed.As a result, the treating surgeon chose to abort the procedure without opting to try a new hp unit.There were no adverse health consequences to the patient due to this event.
 
Manufacturer Narrative
The aquabeam handpiece was returned for investigation.Visual inspection of the returned device observed to have no physical damages or anomalies.Additionally, no debris was observed along the telescoping tube.Functional testing confirmed the reported event as the scope could not be inserted into the handpiece as the telescoping tube tube was stuck in place.Slight force had to applied to adjust the telescoping tube and and allow it to move properly.Root cause is undeterminable as the scope carriage could be retracted once the telescoping tube was allowed to move freely, and the failure could not be consistently produced.A review of the device history record (dhr) ab2000-b / serial number (b)(6) and aquabeam handpiece / lot number 23c01170 was conducted, which confirmed that there were no non-conformances, failures, discrepancies, or missed steps during the manufacturing process that could be related to the reported event.The review indicated that the system met all design and manufacturing specifications when released for distribution.The aquabeam robotic system user manual, um0101 rev.F, states the following: 11.2.5 sterile: aquabeam handpiece and aquabeam scope setup using the knobs on the carriage, advance the aquabeam scope forwards (distal) and backwards (proximal) to ensure that the aquabeam scope is fully engaged with the aquabeam handpiece.The scope tube tip should move forwards and backwards in concert with the movement of the aquabeam scope.The current instruction for use ifu0101-00 rev.E, aquabeam robotic system ifu, us, english was reviewed.8.30 sterile: treatment a.To begin the aquablation treatment, step on the foot pedal and gently support the beige braided tubing extending from the back of the aquabeam handpiece.Caution (for system models other than ab2000c): failure to support the beige braided tubing may result in a system fault or insufficient cutting efficacy.A.During the aquablation treatment, use [-] indicator on the motorpack to decrease power/resection depth (if needed) and use [+] to increase back to planned power submission of this report does not constitue an admission that the manufacturer's product caused or contributed to the event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AQUABEAM ROBOTIC SYSTEM
Type of Device
FLUID JET REMOVAL SYSTEM
Manufacturer (Section D)
PROCEPT BIOROBOTICS CORPORATION
900 island drive
suite 101
redwood city CA 94065
Manufacturer (Section G)
PROCEPT BIOROBOTICS CORPORATION
900 island drive
suite 101
redwood city CA 94065
Manufacturer Contact
doria esquivel
900 island drive
suite 101
redwood city, CA 94065
6502327291
MDR Report Key17262613
MDR Text Key318593158
Report Number3012977056-2023-00105
Device Sequence Number1
Product Code PZP
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
DEN170024
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 09/12/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberAB2000
Device Catalogue NumberAB2000
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 06/15/2023
Initial Date FDA Received07/05/2023
Supplement Dates Manufacturer Received08/17/2023
Supplement Dates FDA Received09/12/2023
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured10/13/2021
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
Patient SexMale
-
-