Model Number 1217-20-500
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Fall (1848); Fatigue (1849); Pain (1994); Joint Laxity (4526)
Event Date 03/06/2023
Event Type  Injury  
Manufacturer Narrative
Product complaint # (b)(4).E3 initial reporter occupation: (b)(6).Follow-up is being conducted to obtain legal contact information.If/when the contact information is received, a supplemental med watch report will be submitted.Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
On (b)(6) 2023, the patient had a revision left hip with removal of acetabular cup, screws x5, and placement of competitor cup and screws x4, along with depuy femoral head.Prior to surgery, the patient was experiencing instability.During the procedure, the surgeon observed weakness of the gluteus maximus muscle.The dual mobility head was revised, along with the liner.Doi: (b)(6) 2022; dor: (b)(6) 2023; left hip.
 
Manufacturer Narrative
Product complaint (b)(4).Investigation summary; no device associated with this report was received for examination.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.Depuy considers the investigation closed.Should additional information be received, the information will be reviewed and the investigation will be re-opened as necessary.Device history lot; a manufacturing record evaluation (mre), was not possible because the required lot code was not provided.
 
Event Description
Medical records were received: doe: (b)(6) 2022: patient presents with pain and feelings of instability in her left hip.X rays identify a well-fixed and stable tha.Patient is treated with physical therapy and oral medication.Doe (b)(6) 2022: patient received a closed reduction of the left hip to treat a dislocation after a slip and fall while feeding her cat.The procedure was completed without complications.The patient is prescribed additional physical therapy.Patient continued to experience pain and instability after physical therapy and on 03 february 2023, the patient was referred for revision to treat the instability and pain secondary to dislocation of the left hip following a fall.(b)(6) 2023: patient received a left hip revision to treat instability and pain secondary to a dislocation after a fall.The femoral stem was stable and retained.The cup, screws, and dual mobility head/liner were revised and replaced with competitor products.The procedure was completed without complications.The dislocation treated with closed reduction and the revision to treat instability are continuations of the same event.Doi: (b)(6) 2023.Doe: (b)(6) 2022.Dor: (b)(6) 2023.Left hip.
 
Manufacturer Narrative
Product complaint # (b)(4).This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by depuy synthes joint reconstruction, or its employees that the report constitutes an admission that the product, depuy synthes joint reconstruction, or its employees caused or contributed to the potential event described in this report.H10 additional narrative: if information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PINN CAN BONE SCREW 6.5MMX20MM
Type of Device
BONE SCREWS AND PINS : SCREWS
Manufacturer (Section D)
DEPUY ORTHOPAEDICS INC US
700 orthopaedic drive
warsaw IN 46581 0988
Manufacturer (Section G)
DEPUY ORTHOPAEDICS, INC. 1818910
700 orthopaedic dr.
warsaw IN 46581 0988
Manufacturer Contact
kate karberg
700 orthpaedic dr.
warsaw, IN 46581
3035526892
MDR Report Key17266369
MDR Text Key318576908
Report Number1818910-2023-13634
Device Sequence Number1
Product Code LPH
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K983014
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other
Reporter Occupation Other
Type of Report Initial,Followup,Followup
Report Date 07/06/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Model Number1217-20-500
Device Catalogue Number121720500
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 06/22/2023
Initial Date FDA Received07/06/2023
Supplement Dates Manufacturer Received07/07/2023
07/27/2023
Supplement Dates FDA Received07/25/2023
07/28/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Treatment
BI MENTUM PFRK PE LINER 28 53; DELTA CER HEAD 12/14 28MM +1.5; PINN CAN BONE SCREW 6.5MMX20MM; PINN CAN BONE SCREW 6.5MMX35MM; PINN CAN BONE SCREW 6.5MMX50MM; PINNACLE DM LINER 62_53; UNKNOWN HIP ACETABULAR CUP; UNKNOWN SCREW
Patient Outcome(s) Required Intervention;
Patient Age70 YR
Patient SexFemale
-
-