• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ARROW INTERNATIONAL LLC ARROW HEMODIALYSIS SET: 2-LUMEN 12 FR X 20 CM; CATHETER HEMODIALYTSIS NON IMP

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARROW INTERNATIONAL LLC ARROW HEMODIALYSIS SET: 2-LUMEN 12 FR X 20 CM; CATHETER HEMODIALYTSIS NON IMP Back to Search Results
Model Number IPN030147
Device Problem Leak/Splash (1354)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 06/08/2023
Event Type  malfunction  
Manufacturer Narrative
Qn#(b)(4).
 
Event Description
It was reported the arrow raulerson syringe (ars) was found leaking during use on the patient.No patient harm was reported.The patient's condition is reported as fine.
 
Event Description
It was reported the arrow raulerson syringe (ars) was found leaking during use on the patient.No patient harm was reported.The patient's condition is reported as fine.
 
Manufacturer Narrative
(b)(4).The issue of ars leaking could not be confirmed during functional testing of the returned sample.The customer returned one arrow ra ulerson syringe (ars) for evaluation.No definite signs-of-use in the form of biological material were observed on the returned components.Visual examination of the ars did not reveal any anomalies or defects.The returned sample was functionally tested using a lab inventory 18ga introducer needle in accordance with the instructions-for-use provided with this kit.The ifu states, "insert introducer needle or catheter/needle with attached syringe or arrow raulerson syringe (where provided) into vein and aspirate." the ars was able to successfully draw and aspirate water with and without the introducer needle attached.The module requirement document for raulerson syringes was reviewed to determine requirements for air/water leakage.The document noted a deviation from iso: "the freedom of air and liquid leakage past the piston requirement is design restrictive and is intended for an injection-intended syringe, not the ars.The opening in the center of the piston that allows passage of the inner cannula prohibits the ars from meeting the pressure and vacuum requirements as dictated by the standard.However, because the intended use of the ars is to allow aspiration of blood to ensure venous placement of the introducer needle and to aid in the insertion of the spring wire guide, the leakage requirements of a standard syringe are not applicable to the ars." a vacuum test was performed on the ars syringes to verify that the internal valves within the plunger body were intact.With the plunger body at the bottom of the syringe, the tip of the ars was occluded, and the plunger was pulled back.With the tip of the ars still occluded, the plunger was released and did snap back.Therefore, the internal valves of the ars were functioning as intended.A device history record review was performed, and no relevant findings were identified.No problem was found with the returned device.Teleflex will continue to monitor and trend for reports of this nature.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ARROW HEMODIALYSIS SET: 2-LUMEN 12 FR X 20 CM
Type of Device
CATHETER HEMODIALYTSIS NON IMP
Manufacturer (Section D)
ARROW INTERNATIONAL LLC
morrisville NC
Manufacturer (Section G)
ARROW INTERNATIONAL CR, A.S.
jamska 2359/47
zdar nad sazavou 591 0 1
EZ   591 01
Manufacturer Contact
kevin don bosco
3015 carrington mill blvd
morrisville, NC 27560
MDR Report Key17276124
MDR Text Key318570788
Report Number3006425876-2023-00641
Device Sequence Number1
Product Code MPB
Combination Product (y/n)N
Reporter Country CodeCH
PMA/PMN Number
K993933
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,User Facility,Company Representative,Distributor
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 06/12/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Model NumberIPN030147
Device Catalogue NumberCS-25122-F
Device Lot Number71F23A1452
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 06/12/2023
Initial Date FDA Received07/06/2023
Supplement Dates Manufacturer Received07/26/2023
Supplement Dates FDA Received07/28/2023
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured01/25/2023
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Treatment
NOT REPORTED; NOT REPORTED
-
-