• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: THORATEC SWITZERLAND GMBH CENTRIMAG 2ND GENERATION PRIMARY CONSOLE; CONTROL, PUMP SPEED, CARDIOPULMONARY BYPASS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

THORATEC SWITZERLAND GMBH CENTRIMAG 2ND GENERATION PRIMARY CONSOLE; CONTROL, PUMP SPEED, CARDIOPULMONARY BYPASS Back to Search Results
Model Number 201-90411
Device Problem Display or Visual Feedback Problem (1184)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 06/22/2023
Event Type  malfunction  
Manufacturer Narrative
No further information was provided.A supplemental report will be submitted once the manufacturer¿s investigation is completed.
 
Event Description
It was reported that when the green power button was pressed to turn the console on, the console made the distinct sound when it normally turns on but the screen remained blank.
 
Manufacturer Narrative
Manufacturer's investigation conclusion: incidental finding: damaged top housing.The reported event of the centrimag console screen remaining blank when powering on the system was confirmed via analysis of the returned unit.The returned centrimag console (serial number: (b)(6)) was evaluated at the european distribution center (edc), alongside known working test centrimag equipment.Upon powering on the console, it was observed that no information would display on the screen.The unit was disassembled to further inspect the internal components, revealing that the screen on the screen printed circuit board (pcb) was cracked.Damage to this component would result in the reported event.The damaged screen pcb was then replaced with a new screen pcb.After replacing the damaged screen pcb, a full functional checkout was performed and the unit passed all steps of the test without any issues.The serviced and repaired unit was returned to the customer site after passing all tests per procedure.A log file was downloaded from the returned centrimag console during testing.The data in the log file did not indicate any issues with the centrimag console.No atypical events were observed within the timeframe of the reported event date of 22jun2023.The reported event was determined to be due damage to the centrimag console¿s screen; however, the root cause of the damage could not be conclusively determined through this analysis.The device history records were reviewed and the records revealed that the centrimag console, serial number (b)(6), was manufactured in accordance with manufacturing and qa specifications.The 2nd generation centrimag system operating manual section 9 ¿ ¿emergencies/troubleshooting¿ provides instructions for operation when there is a need to exchange the main console or motor with a backup console or motor.The recommended practice whenever there is a console or motor malfunction is to replace the console and motor as a set.Remove the blood pump from the malfunctioning motor and console and place the blood pump in the back-up motor and console.Switch all components (console, motor, flow probe and cables) simultaneously to continue patient support, and then perform troubleshooting on the non-functioning system, when it is no longer being used for patient support.The 2nd generation centrimag system operating manual section 8.3 ¿ ¿recommended preventive maintenance¿ instructs users to regularly inspect the console for signs of damage and to return the console back to thoratec for servicing if any damage is observed.No further information was provided.The manufacturer is closing the file on this event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CENTRIMAG 2ND GENERATION PRIMARY CONSOLE
Type of Device
CONTROL, PUMP SPEED, CARDIOPULMONARY BYPASS
Manufacturer (Section D)
THORATEC SWITZERLAND GMBH
technoparkstrasse 1
zurich CH-80 05
SZ  CH-8005
Manufacturer (Section G)
THORATEC SWITZERLAND GMBH
technoparkstrasse 1
zurich CH-80 05
SZ   CH-8005
Manufacturer Contact
bob fryc
6035 stoneridge drive
pleasanton, CA 94588
7818528204
MDR Report Key17310541
MDR Text Key319238593
Report Number3003306248-2023-01957
Device Sequence Number1
Product Code DWA
UDI-Device Identifier07640135140702
UDI-Public7640135140702
Combination Product (y/n)N
Reporter Country CodeUK
PMA/PMN Number
K131179
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 10/17/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number201-90411
Device Lot Number6407102
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 06/22/2023
Initial Date FDA Received07/12/2023
Supplement Dates Manufacturer Received09/27/2023
Supplement Dates FDA Received10/17/2023
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured03/09/2018
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-