• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: THORATEC SWITZERLAND GMBH CENTRIMAG 2ND GENERATION PRIMARY CONSOLE; CONTROL, PUMP SPEED, CARDIOPULMONARY BYPASS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

THORATEC SWITZERLAND GMBH CENTRIMAG 2ND GENERATION PRIMARY CONSOLE; CONTROL, PUMP SPEED, CARDIOPULMONARY BYPASS Back to Search Results
Model Number 201-30300
Device Problems Failure to Power Up (1476); Insufficient Information (3190); Complete Loss of Power (4015)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 06/29/2023
Event Type  malfunction  
Event Description
It was reported that the centrimag console did not receive power when plugged into the hospital's power.The device did operate with the backup battery, however, during an engineer review of the device it appeared there was an issue with the battery.The device was not in use with a patient at the time of the event.
 
Manufacturer Narrative
No additional information has been provided.A supplemental report will be submitted once the manufacturer's investigation is complete.
 
Manufacturer Narrative
Manufacturer's investigation conclusion: the reported event of the console not operating on ac power and the reported event of the battery not passing battery maintenance were not confirmed.The centrimag 2nd generation primary console (serial #: (b)(6) was not returned for analysis.Additional provided information communicated on 08jul2023 stated that the cause of lack of energy was not identified because when the engineer attended, he did not show an issue or any related alarm.At the moment, it is working well in that it did not present this specific problem again.Additional provided information communicated on 23aug2023 stated that there were no alarms related to the battery issue.The battery did not pass the preventative maintenance twice and needed to be changed, resolving the issue.There are no log files available for review.The battery was exchanged but it will not be returned for analysis; it was scrapped.The root cause for the reported events were unable to be conclusively determined through this analysis.The device history records were reviewed for the centrimag 2nd generation primary console (serial #: (b)(6) and the console was found to pass all manufacturing and quality assurance (qa) specifications.The 2nd generation centrimag system operating manual section 4 entitled "warnings & precautions" warns "one additional 2nd generation centrimag primary console, motor and flow probe are required as backup system in the immediate vicinity of each patient whenever the centrimag or pedivas blood pump is used.The backup console must be connected to the backup motor and to the backup flow probe, have a battery charge sufficient for at least one hour of operation, be connected to ac power (except during transport) and be immediately available should the main console, motor or flow probe experience a malfunction." the 2nd generation centrimag system operating manual section 10 entitled "emergency and troubleshooting" states that "the recommended practice whenever there is a 2nd generation centrimag primary console or motor malfunction is to replace the console and motor as a set.Remove the blood pump from the malfunctioning motor and console and place the blood pump in the backup motor and console to continue patient support.Do not exchange individual motors or individual consoles during patient support." the 2nd generation centrimag system operating manual table 15 entitled ¿console maintenance schedule¿ states to replace the internal battery every 2 years and perform battery maintenance every 6 months.No further information was provided.The manufacturer is closing the file on this event.
 
Event Description
Additional information reported that the battery was exchanged, and the issue resolved.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CENTRIMAG 2ND GENERATION PRIMARY CONSOLE
Type of Device
CONTROL, PUMP SPEED, CARDIOPULMONARY BYPASS
Manufacturer (Section D)
THORATEC SWITZERLAND GMBH
technoparkstrasse 1
zurich CH-80 05
SZ  CH-8005
Manufacturer (Section G)
THORATEC SWITZERLAND GMBH
technoparkstrasse 1
zurich CH-80 05
SZ   CH-8005
Manufacturer Contact
bob fryc
6035 stoneridge drive
pleasanton, CA 94588
7818528204
MDR Report Key17326245
MDR Text Key319317435
Report Number3003306248-2023-01962
Device Sequence Number1
Product Code DWA
Combination Product (y/n)N
Reporter Country CodeCO
PMA/PMN Number
K131179
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 09/05/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number201-30300
Device Lot Number8885309
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 06/29/2023
Initial Date FDA Received07/14/2023
Supplement Dates Manufacturer Received08/31/2023
Supplement Dates FDA Received09/05/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured04/05/2011
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-