• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: C.R. BARD, INC. (COVINGTON) -1018233 BARDEX® LUBRI-SIL® ALL-SILICONE FOLEY CATHETER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

C.R. BARD, INC. (COVINGTON) -1018233 BARDEX® LUBRI-SIL® ALL-SILICONE FOLEY CATHETER Back to Search Results
Catalog Number 175816
Device Problem Incorrect Measurement (1383)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 08/10/2023
Event Type  malfunction  
Event Description
It was reported that in an online survey a physician stated that they were not able to successfully place the foley catheter in a patient as the catheter was smaller in size in relation to tr17585m16 - 16 fr lubr-sil® standard length bard® hydrogel coated all- silicone foley catheter, pre-connected to bardia® b500m (500ml) leg bag.
 
Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.H11: section a through f - the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : the device was not returned.
 
Manufacturer Narrative
The reported event was inconclusive because no sample was returned.The potential root cause for this failure could be "improperly molded or extruded, incorrect size selected".The lot number was unknown; therefore, the device history record could not be reviewed.The instructions for use were found adequate and state the following: "inspect the product for any imperfections or surface deterioration prior to use.If package is opened or if any imperfection or surface deterioration is observed, do not use.1.Open outer white wrapping to prepare sterile field and place underpad beneath patient, plastic side down.2.If patient has a catheter in-situ to deflate catheter balloon: gently insert a luer slip tip syringe in the catheter valve.Never use more force than is required to make the syringe ¿stick¿ in the valve.Allow the pressure within the balloon to force the plunger back and fill the syringe with water.If you notice slow or no deflation, reseat the syringe gently.Use only gentle aspiration to encourage deflation if needed.Vigorous aspiration may collapse the inflation lumen, preventing balloon deflation.Wait at least 30 seconds for deflation.If permitted by local protocol, the valve arm may be severed.If this fails, contact adequately trained professional for assistance as directed by local protocol.Should balloon rupture occur, care should be taken to assure that all balloon fragments have been removed from the patient.3.Put on gloves, cover patient with fenestrated drape with open exposing location where catheter will be inserted, and place the apron on yourself.4.Using the two (2) syringes, marked ¿for cleansing purposes only¿, dispense the water onto three (3) gauze squares.Prepare the patient by wiping down the catheter insertion site with the saturated gauze squares.Dry patient with the remaining two (2) gauze squares.Note: do not use this syringe to inflate the catheter balloon.5.Prepare the lubricating gel syringe by removing the cap from the syringe tip.6.For easing with the insertion of the catheter into the patient dispense the lubricating gel into the urethra (according to local protocol).7 remove top tray and open plastic pouch (sleeve) surrounding the catheter.8.Proceed with catheterisation according to local protocol.To inflate catheter, simply insert tip of sterile water-filled syringe gently into valve (do not overpenetrate) and depress plunger.Instill entire amount of sterile water - 10 ml.9.Attach statlock® foley stabilisation device to the bifurcation (y-shape) of the foley catheter (statlock® foley stabilisation device can be used for up to 7 days) and apply.(refer to the instructions for use provided with the statlock® foley stabilisation device pouch for more details).10.If the procedure pack includes a leg bag, utilise the leg straps provided to secure the leg bag to the patient¿s leg, making sure not to affect circulation or drainage of urine.11.Ensure catheter and drainage bag tubing is kink free and drainage bag is positioned below the bladder to ensure urine is flowing freely.Periodic inspection of this system should be made to ensure that urine is flowing freely.If a standing column of urine is observed, check for correct positioning of bag and then for a physical obstruction.If correct positioning or removal of physical obstruction does not allow free flow, further investigation should be taken in line with local protocol".H11: section a through f - the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
 
Event Description
It was reported that in an online survey a physician stated that they were not able to successfully place the foley catheter in a patient as the catheter was smaller in size in relation to tr17585m16 - 16 fr lubr-sil® standard length bard® hydrogel coated all- silicone foley catheter, pre-connected to bardia® b500m (500ml) leg bag.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BARDEX® LUBRI-SIL® ALL-SILICONE FOLEY CATHETER
Type of Device
SILICONE FOLEY CATHETER
Manufacturer (Section D)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington 30014
Manufacturer (Section G)
C.R. BARD INC. (COVINGTON) -1018233
8195 industrial blvd
covington 30014
Manufacturer Contact
xeeroy rada
8195 industrial blvd
covington 30014
7707846100
MDR Report Key17633189
MDR Text Key322101176
Report Number1018233-2023-06395
Device Sequence Number1
Product Code EZL
UDI-Device Identifier00801741034169
UDI-Public(01)00801741034169
Combination Product (y/n)N
Reporter Country CodeUK
PMA/PMN Number
K040504
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Study
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 10/12/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number175816
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 08/10/2023
Initial Date FDA Received08/28/2023
Supplement Dates Manufacturer Received10/11/2023
Supplement Dates FDA Received10/13/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other;
Patient SexMale
-
-