Device Problem Computer Software Problem (1112)
Patient Problems Insufficient Information (4580); No Clinical Signs, Symptoms or Conditions (4582)
Event Date 07/13/2023
Event Type  malfunction  
Manufacturer Narrative
The manufacturer's investigation is on-going and further information will be provided once the investigation has completed.
 
Event Description
" the customer reported that disconnections on the sequencer caused the delivered treatment to fail to record in mosaiq.
 
Manufacturer Narrative
H2 updated h6 updated h10 updated from the mosaiq logs the investigation found that the issue of the lost connection was due to a workstation lock-up.When this happens the prescribed treatment is delivered, as intended; however, the sequencer application is no longer in operation to receive the treatment verification and record the provided treatment information.Review of the record, user messages, and/or in operation of the software will make clear to the user that the provided treatment has not been recorded.As the treatment is delivered as prescribed, no serious injury would be foreseeable if the event were to recur.When the communication was re-established and the patient's treatment calendar was accessed the user was presented with a "treatment delivery not complete" warning message.The user acknowledged this message, however the user did not perform a manual recording at this time, but was certain that only 261.3 mu had been given and delivered the remaining 45 mu using the complete partial option.Based on the customers actions, a manual recording of 261.3 should be entered.Mosaiq worked as designed and intended.Based on available information there was no mistreatment.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MOSAIQ
Type of Device
ACCELERATOR, LINEAR, MEDICAL
Manufacturer (Section D)
ELEKTA SOLUTIONS AB
kungstensgatan 18
box 7593
stockholm, SE-10 3 93
SW  SE-103 93
Manufacturer (Section G)
ELEKTA SOLUTIONS AB
400 perimeter center terrace
suite 50
atlanta GA 30346
Manufacturer Contact
cornerstone
london road
crawley, west sussex RH10 -9BL,
MDR Report Key17660733
MDR Text Key322374828
Report Number3015232217-2023-00050
Device Sequence Number1
Product Code IYE
UDI-Device Identifier00858164002282
UDI-Public(01)00858164002282(10)2.81.070
Combination Product (y/n)N
Reporter Country CodeAU
PMA/PMN Number
K183034
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Foreign,Health Professional,User Facility
Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date 09/25/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? No
Device Operator Health Professional
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 08/01/2023
Initial Date FDA Received08/31/2023
Supplement Dates Manufacturer Received08/01/2023
Supplement Dates FDA Received09/25/2023
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured10/03/2019
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-