BOSTON SCIENTIFIC CORPORATION ROTABLATOR ROTATIONAL ATHERECTOMY SYSTEM; CATHETER, CORONARY, ATHERECTOMY Back to Search Results
Device Problem Entrapment of Device (1212)
Patient Problems High Blood Pressure/ Hypertension (1908); Ischemia (1942)
Event Date 01/01/2023
Event Type  Injury  
Manufacturer Narrative
Date of event: (b)(6) 2023 used as approximate event date as actual event date is unknown.
 
Event Description
It was reported that the burr became stuck in lesion and patient experienced myocardial ischemia and unstable blood pressure.The severely stenosed with delayed flow target lesion was located in the severely calcified mid left anterior descending artery.A rotablator was selected for use.During the procedure, the burr suddenly entrapped in the culprit lesion, leading to broad anterior myocardial ischemia and unstable blood pressure.Intra-aortic balloon pumping was immediately inserted via right femoral artery, and double guide catheter technique was adopted via left femoral artery.A new guide wire in the second system was crossed beside the stuck burr, and small size balloon could cross and was dilated, which lead to successful removal of the stuck burr.Finally, two drug-eluting stents were implanted, and the procedure was successfully conducted.No further patient complications were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ROTABLATOR ROTATIONAL ATHERECTOMY SYSTEM
Type of Device
CATHETER, CORONARY, ATHERECTOMY
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC LTD
model farm road
cork
EI  
Manufacturer Contact
rachel shields
4100 hamline ave n
arden hills, MN 55112
6512422111
MDR Report Key17714291
MDR Text Key323001832
Report Number2124215-2023-49074
Device Sequence Number1
Product Code MCX
Combination Product (y/n)N
Reporter Country CodeUS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Literature,Company Representative
Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date 09/08/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 08/18/2023
Initial Date FDA Received09/08/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
Patient Age76 YR
Patient SexFemale
-
-