Model Number 0673
Device Problems Device Dislodged or Dislocated (2923); Material Integrity Problem (2978); Positioning Problem (3009)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 09/07/2023
Event Type  malfunction  
Manufacturer Narrative
The device has not been received for analysis.Upon receipt and completion of the failure analysis of the complaint device, if there is any further relevant information from that review, a supplemental report will be filed.
 
Event Description
It was reported that this right ventricular (rv) lead was attempted implant due to helix was bent and it was difficult to position that causes it to dislodge.The physician notice that it was seeing atrial signals due to lead was flipped up into atrium.The physician tried repositioning the lead but can't get optimal numbers.This lead was never in service and was replace with a new one.No additional adverse patient effects were reported.
 
Event Description
It was reported that this right ventricular (rv) lead was attempted implant due to helix was bent and it was difficult to position that causes it to dislodge.The physician notice that it was seeing atrial signals due to lead was flipped up into atrium.The physician tried repositioning the lead but can't get optimal numbers.This lead was never in service and was replace with a new one.No additional adverse patient effects were reported.
 
Manufacturer Narrative
The device has not been received for analysis.Upon receipt and completion of the failure analysis of the complaint device, if there is any further relevant information from that review, a supplemental report will be filed.Upon receipt at our post market quality assurance laboratory, a thorough evaluation of the lead was performed.Testing was completed to assess lead electrical performance and inner/outer insulation integrity.Measurements were within normal limits.Microscopic inspections of the terminal pin assembly, lead body, and electrode tip found no anomalies.Laboratory testing was unable to reproduce the reported clinical observations and detailed analysis did not reveal any abnormalities.A helix mechanism test itself passed within the required number of turns, however, the helix is slightly deformed.Due to the helix being deformed - the helix rubs on the helix housing sidewall while being extended and retracted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RELIANCE 4-FRONT
Type of Device
IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (NON-CRT)
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
4100 hamline avenue north
saint paul MN 55112
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
road 698, lot no. 12
dorado PR 00646 -260
*   00646-2602
Manufacturer Contact
timothy degroot
4100 hamline avenue north
saint paul, MN 55112
6515826168
MDR Report Key17761225
MDR Text Key323580321
Report Number2124215-2023-50640
Device Sequence Number1
Product Code LWS
UDI-Device Identifier00802526592867
UDI-Public00802526592867
Combination Product (y/n)Y
Reporter Country CodeUS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 11/06/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number0673
Device Catalogue Number0673
Device Lot Number204374
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/14/2023
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 09/07/2023
Initial Date FDA Received09/15/2023
Supplement Dates Manufacturer Received10/18/2023
Supplement Dates FDA Received11/06/2023
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured06/29/2023
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Age77 YR
Patient SexMale
-
-