ZIMMER BIOMET, INC. RINGLOC BI-POLAR 28X52MM; PROSTHESIS, HIP Back to Search Results
Model Number N/A
Device Problems Difficult to Insert (1316); Material Twisted/Bent (2981)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 09/09/2023
Event Type  malfunction  
Manufacturer Narrative
(b)(4).D10: cat# 163669 lot# j7384314 32mm mod head cocr std neck.G2: foreign ¿ (b)(6).The customer has indicated that the product is in process of being returned to zimmer biomet for investigation.Once the investigation has been completed, a follow-up mdr will be submitted.
 
Event Description
It was reported by the surgeon that during an initial hip procedure, the ring of the cup was bent so the cup could not be inserted into the liner.New products were used to complete the surgery.There was no known impact or consequences to the patient.Attempts have been made and no further information has been provided.
 
Manufacturer Narrative
(b)(4).This follow-up report is being submitted to relay additional information.The following sections were updated/corrected: updated: b4; b5; d4; d9; g3; h2; h3; h4; h6.Visual examination of the returned product identified the locking ring was bent inside of the shell.The chamfer was returned in the correct position.The liner shows an indentation on the outer radius.The width and thickness of the locking ring were checked per the print and found within conformance.It is unknown if the deformation occurred during or prior to the assembly attempt.Complaint confirmed based on evaluation of the returned product.Dhr was reviewed and no discrepancies related to the reported event were found.A definitive root cause cannot be determined.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Event Description
No additional event information to report at this time.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RINGLOC BI-POLAR 28X52MM
Type of Device
PROSTHESIS, HIP
Manufacturer (Section D)
ZIMMER BIOMET, INC.
56 e. bell drive
p.o. box 587
warsaw IN 46581
Manufacturer (Section G)
ZIMMER BIOMET, INC.
56 e. bell drive
p.o. box 587
warsaw IN 46581
Manufacturer Contact
jennifer rapsavage
56 e. bell dr.
warsaw, IN 46582
5745260384
MDR Report Key17867937
MDR Text Key324880019
Report Number0001825034-2023-02300
Device Sequence Number1
Product Code JDI
Combination Product (y/n)N
Reporter Country CodeMX
PMA/PMN Number
K051569
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 01/05/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberN/A
Device Catalogue Number11-165228
Device Lot Number364920
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 09/09/2023
Initial Date FDA Received10/04/2023
Supplement Dates Manufacturer Received01/02/2024
Supplement Dates FDA Received01/05/2024
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured10/17/2019
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Removal/Correction NumberN/A
Patient Sequence Number1
Treatment
SEE H10 NARRATIVE.
Patient Age82 YR
Patient SexMale
Patient Weight65 KG
-
-