Model Number N/A
Device Problems Material Erosion (1214); Patient Device Interaction Problem (4001)
Patient Problems Failure of Implant (1924); Inflammation (1932); Necrosis (1971); Pain (1994); Metal Related Pathology (4530)
Event Date 09/13/2022
Event Type  Injury  
Event Description
It was reported that the patient underwent an initial right total hip arthroplasty.Subsequently, the patient was revised approximately 13 years later due to pain, elevated cobalt chrome levels, and mri evidence of trunnionosis.During the revision, necrotic tissue was debrided with trunnionosis noted at the head/neck junction.The stem and shell were well-fixed and left in place.A new locking ring, poly liner, ceramic head, and neck were placed without complications.Attempts have been made and no further information has been provided.
 
Manufacturer Narrative
(b)(4).Multiple mdr reports were filed for this event, please see associated reports: 0001822565 - 2023 - 01833, 0001822565 - 2023 - 01834.D10: cat# 00625006525 lot# 61288013 bone scr 6.5x25 self-tap.Cat# 00771301200 lot# 61265772 modular femoral stem press-fit plasma sprayed cementless size 12.5.Cat# 00620005622 lot# 61237887 shell porous with cluster holes 56 mm o.D.Proposed component code: mechanical (g04)- head.No product was returned or pictures provided; visual and dimensional evaluations could not be performed.Review of the device history records identified no deviations or anomalies during manufacturing.Medical records were provided and reviewed by a health care professional.Review of the available records identified the following: an initial right tha was performed.A revision occurred due to pain and elevated metal ions.During the revision, trunnionosis and alval was identified, with poly wear as well.A definitive root cause cannot be determined.This report was previously report under 0001822565 - 2023 - 01831.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FEMORAL HEAD STERILE PRODUCT DO NOT RESTERILIZE 12/14 TAPER
Type of Device
PROSTHESIS, HIP
Manufacturer (Section D)
ZIMMER MANUFACTURING B.V.
turpeaux industrial park
route #1 km 123.4 bldg #1
mercedita PR 00715
Manufacturer (Section G)
ZIMMER MANUFACTURING B.V.
turpeaux industrial park
route #1 km 123.4 bldg #1
mercedita PR 00715
Manufacturer Contact
jennifer rapsavage
56 e. bell dr.
warsaw, IN 46582
5745260384
MDR Report Key17929696
MDR Text Key325571059
Report Number0002648920-2023-00247
Device Sequence Number1
Product Code LPH
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K953337
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Consumer,Health Professional
Reporter Occupation Physician
Type of Report Initial
Report Date 10/11/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date07/31/2019
Device Model NumberN/A
Device Catalogue Number00801803602
Device Lot Number61287037
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 10/10/2023
Initial Date FDA Received10/13/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured07/13/2009
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Removal/Correction NumberN/A
Patient Sequence Number1
Patient Outcome(s) Hospitalization; Required Intervention;
Patient SexMale
-
-