Model Number 30-401LITE
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem Burn(s) (1757)
Event Date 09/13/2023
Event Type  Injury  
Manufacturer Narrative
(b)(4).Hologic is submitting this report in accordance with 21.Cfr part 803.The submission is based upon the currently available information.The submission of this report does not represent a confirmation of device malfunction involving the hologic products in the event described.D4: lot and serial number of the device not provided by the complainant; therefore, the udi, expiration and manufacturing dates are not known.Device history record (dhr) review was unable to be conducted for the disposable device as the identification numbers were not provided by the complainant.H3: the device involved in this event was not returned for evaluation purposes therefore visual and functional analysis of the product could not be performed.We are unable to confirm a relationship between the device and the issue reported and a definitive root cause for the reported event could not be determined.The information obtained during complaint investigation will be included in our global complaint trending and product surveillance will continue to monitor complaints of this type for adverse trends.If the product is received or additional information is obtained, the investigation will be reopened accordingly per standard operating procedure.3 devices were involved in this event: 1222780-2023-00391 and 1222780-2023-00393.
 
Event Description
It was reported that on (b)(6), an acessa procedure, hysteroscopy procedure, and myosure procedure were performed on the same patient and the patient presented to the doctor 2 weeks post-operation and was informed of circular burn mark on the left side of her buttocks.Both myosure and acessa procedures were completed.The patient is paraplegic due to a car accident.The patient has a metal rod in the mid back.Rod is located above the uterus.The doctor.Reviewed any and all contraindications with the patient and chose to proceed with the myosure and acessa procedures.The patient did have a bovie leg pad (not an acessa leg pad) on the right side leg during the acessa procedure.The patient was using hydrogen peroxide to clean the area and it was not healing.The patient was told by the doctor to use neosporin to tend to burn marks.No additional information available.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MYOSURE LITE TISSUE REMOVAL DEVICE
Type of Device
HYSTEROSCOPE (AND ACCESSORIES)
Manufacturer (Section D)
HOLOGIC, INC
250 campus drive
marlborough MA 01752
Manufacturer (Section G)
HOLOGIC, INC.
250 campus drive
marlborough MA 01752
Manufacturer Contact
ariel lafuente
562 parkway
coyol free zone building b24
san jose 20102
CR   20102
MDR Report Key17964755
MDR Text Key326027861
Report Number1222780-2023-00392
Device Sequence Number1
Product Code HIH
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K142029
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type User Facility,Company Representative
Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date 10/18/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Model Number30-401LITE
Device Catalogue Number30-401LITE
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 10/04/2023
Initial Date FDA Received10/19/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other;