BOSTON SCIENTIFIC NEUROMODULATION VERCISE CARTESIA; STIMULATOR, ELECTRICAL, IMPLANTED, FOR PARKINSONIAN SYMPTOMS Back to Search Results
Model Number DB-2202-45
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem Erosion (1750)
Event Date 10/11/2023
Event Type  Injury  
Event Description
It was reported that the patient underwent a revision of their deep brain stimulation (dbs) burr hole cover site on the scalp.The physician assessed that the dbs lead strain relief loop had migrated superior throughout the healing-scar formation and started to erode the skin-incision.There was no issue with the burr hole cover.During the revision the physician opened the incision, manipulated the lead to ensure that it was flat again, and closed.There were no devices implanted or explanted.The patient has fully recovered.
 
Manufacturer Narrative
Additional suspect medical device components involved in the event: product family: dbs-lead fixation: upn: m365db4600c0.Model: db-4600c.Serial: not applicable.Lot: 28653221.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VERCISE CARTESIA
Type of Device
STIMULATOR, ELECTRICAL, IMPLANTED, FOR PARKINSONIAN SYMPTOMS
Manufacturer (Section D)
BOSTON SCIENTIFIC NEUROMODULATION
25155 rye canyon loop
valencia CA 91355
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
road 698, lot no. 12
dorado PR 00646 -260
*   00646-2602
Manufacturer Contact
erik sherburne
25155 rye canyon loop
valencia, CA 91355
7632920920
MDR Report Key18015962
MDR Text Key326676598
Report Number3006630150-2023-06570
Device Sequence Number1
Product Code NHL
UDI-Device Identifier08714729905288
UDI-Public08714729905288
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P150031
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial
Report Date 10/26/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Expiration Date02/07/2024
Device Model NumberDB-2202-45
Device Catalogue NumberDB-2202-45
Device Lot Number7089097
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received Not provided
Initial Date FDA Received10/26/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured02/07/2022
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
Patient Age75 YR
Patient SexFemale
-
-