Catalog Number D134721IL
Device Problem Mechanical Jam (2983)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 10/12/2023
Event Type  malfunction  
Manufacturer Narrative
The bwi product analysis lab received the device for evaluation.The analysis has begun but is not completed at this time.When the investigational analysis has been completed, a supplemental 3500a report will be submitted.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by biosense webster, inc., or its employees that the report constitutes an admission that the product, biosense webster, inc.Or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.If additional information is received regarding this event, a supplemental 3500a report will be submitted to the fda.Manufacturer's reference number: (b)(4).
 
Event Description
It was reported that a patient underwent an atrial fibrillation (afib) - paroxysmal ablation procedure with a thermocool® smart touch® sf uni-directional navigation catheter and during the operation, the catheter was unable to deflect or relax completely.The catheter was completely stuck in a full deflected position.There was no difficulty in removing the catheter.A second device was used to complete the operation.There was no adverse event reported on patient.
 
Manufacturer Narrative
23-nov-2023, the product investigation was completed.It was reported that a patient underwent an atrial fibrillation (afib) - paroxysmal ablation procedure with a thermocool® smart touch® sf uni-directional navigation catheter and during the operation, the catheter was unable to deflect or relax completely.The catheter was completely stuck in a full deflected position.There was no difficulty in removing the catheter.A second device was used to complete the operation.There was no adverse event reported on patient.Device evaluation details: the device was returned to biosense webster (bwi) for evaluation.A visual inspection and deflection test of the returned device were performed following bwi procedures.Visual analysis revealed several kink along the shaft, no other damage was observed.The damage observed could be related to the manipulation of the device during the procedure, however, this can not be conclusively determined.A deflection test was performed, and despite the kink along the shaft, the curve was deflection within specifications.No deflection issues were observed.A manufacturing record evaluation was performed for the finished device number lot 31029815l and no internal actions related to the complaint were found during the review.The issue reported by the customer could not be replicated during the product investigation; other issues or circumstances may have occurred during the usage of the device that compromised its performance.As part of biosense webster¿s quality process, all devices are manufactured, inspected, and released to approved specifications.If additional information is received regarding this event, a supplemental 3500a report will be submitted to the fda.Manufacturer's reference number: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
THERMOCOOL® SMART TOUCH® SF UNI-DIRECTIONAL NAVIGATION CATHETER
Type of Device
CARDIAC ABLATION PERCUTANEOUS CATHETER
Manufacturer (Section D)
BIOSENSE WEBSTER INC
31 technology drive, suite 200
irvine CA 92618
Manufacturer (Section G)
BIOSENSE WEBSTER INC (JUAREZ)
circuito interior norte
1820parque industrial salvacar
juarez 32599
MX   32599
Manufacturer Contact
kate karberg
31 technology dr
irvine, CA 92618
3035526892
MDR Report Key18094406
MDR Text Key327658831
Report Number2029046-2023-02578
Device Sequence Number1
Product Code LPB
Combination Product (y/n)N
Reporter Country CodeCH
PMA/PMN Number
P030031/S053
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 12/19/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue NumberD134721IL
Device Lot Number31029815L
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer11/08/2023
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 10/12/2023
Initial Date FDA Received11/08/2023
Supplement Dates Manufacturer Received11/23/2023
Supplement Dates FDA Received12/19/2023
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured04/27/2023
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-