Catalog Number D135303
Device Problem Contamination /Decontamination Problem (2895)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 10/30/2023
Event Type  malfunction  
Manufacturer Narrative
This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by biosense webster inc., or its employees that the report constitutes an admission that the product, biosense webster inc., or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.If additional information is received regarding this event, a supplemental 3500a report will be submitted to the fda.Manufacturer's ref.#(b)(4).
 
Event Description
It was reported that a patient underwent a cardiac ablation procedure with a webster cs catheter with auto id technology and a odd silicone/plastic attachment at the tip of the catheter was found.It was reported they were struggling to advance webster cs catheter with auto id technology and upon pulling it out, they noticed an odd silicone/plastic attachment at the tip of the catheter.There was no patient consequence.Multiple attempts have been made to obtain clarification to this complaint.However, no further information has been made available.
 
Manufacturer Narrative
On 30-jan-2024, the bwi product analysis lab received the complaint device for evaluation.The product analysis has begun but is not completed at this time.When the investigational analysis has been completed, a supplemental 3500a report will be submitted.If additional information is received regarding this event, a supplemental 3500a report will be submitted to the fda.Manufacturer's ref.# (b)(4).
 
Manufacturer Narrative
It was reported that a patient underwent a cardiac ablation procedure with a webster cs catheter with auto id technology and a odd silicone/plastic attachment at the tip of the catheter was found.It was reported they were struggling to advance webster cs catheter with auto id technology and upon pulling it out, they noticed an odd silicone/plastic attachment at the tip of the catheter.There was no patient consequence.Device evaluation details: the device was returned to biosense webster inc (bwi) for evaluation and the evaluation has been completed.A visual inspection evaluation of the returned device was performed following bwi procedures.Visual analysis of the returned sample revealed a plastic foreign material attached to the tip of the device.For this reason, a fourier-transform infrared spectroscopy (ft-ir) analysis was requested and it was concluded that the foreign material is mainly composed of biological-based material.Presumably a tissue or fluid from the patient.A manufacturing record evaluation was performed for the finished device batch number, and no internal actions were identified.The issue reported by the customer was confirmed.It should be noted that product failure is multifactorial.As part of biosense webster¿s quality process, all devices are manufactured, inspected, and released to approved specifications.If additional information is received regarding this event, a supplemental 3500a report will be submitted to the fda.Manufacturer's ref.# pc-(b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
WEBSTER CS CATHETER WITH AUTO ID TECHNOLOGY
Type of Device
CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING
Manufacturer (Section D)
BIOSENSE WEBSTER INC
31 technology drive, suite 200
irvine CA 92618
Manufacturer (Section G)
BIOSENSE WEBSTER INC (JUAREZ)
circuito interior norte
1820parque industrial salvacar
juarez 32599
MX   32599
Manufacturer Contact
kate karberg
31 technology dr
irvine, CA 92618
3035526892
MDR Report Key18145335
MDR Text Key328237022
Report Number2029046-2023-02660
Device Sequence Number1
Product Code DRF
UDI-Device Identifier10846835009972
UDI-Public10846835009972
Combination Product (y/n)N
Reporter Country CodeNZ
PMA/PMN Number
K080425
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative
Reporter Occupation Other
Type of Report Initial,Followup,Followup
Report Date 11/15/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue NumberD135303
Device Lot Number31011285M
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received Not provided
Initial Date FDA Received11/15/2023
Supplement Dates Manufacturer Received01/30/2024
02/19/2024
Supplement Dates FDA Received01/31/2024
03/01/2024
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured02/21/2023
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-