Catalog Number 1003330
Device Problems Leak/Splash (1354); Loose or Intermittent Connection (1371)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 08/27/2023
Event Type  malfunction  
Manufacturer Narrative
The device was not returned for analysis.A review of the lot history record identified no manufacturing nonconformities issued to the reported lot that would have contributed to this event.Additionally, a review of the complaint history identified no other incidents from this lot.It is possible that the devices were not properly aligned and/or not fully connected/tightened while attempting to connect thus resulting in the reported loose/intermittent connection and resulting in the reported leak; however as the device was not returned for analysis this cannot be confirmed.The investigation was unable to determine a conclusive cause for the reported loose/intermittent connection and leak.There is no indication of a product quality issue with respect to manufacture, design or labeling.
 
Event Description
It was reported that the patient presented with an acute inferior myocardial infarction and the procedure was to treat a lesion in the mid left anterior descending (mlad) artery with moderate stenosis.The guide wire accessory kit copilot could not be tightly connected to the ring handle syringe and became loose resulting in contrast agent leakage.The seal that leaked was the bleedback control seal.Another guide wire accessory kit copilot was use to complete the procedure.There was no adverse patient effect and there was no clinically significant delay in the procedure.No additional information was provided.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GUIDE WIRE ACC.KIT W/COPILOT®
Type of Device
ACCESSORIES
Manufacturer (Section D)
ABBOTT VASCULAR
26531 ynez rd.
temecula CA 92591 4628
Manufacturer (Section G)
ABBOTT VASCULAR, REG # 2024168
26531 ynez road
temecula CA 92591 4628
Manufacturer Contact
lindsey bell
26531 ynez rd.
temecula, CA 92591-4628
9519143996
MDR Report Key18152596
MDR Text Key328618605
Report Number2024168-2023-12771
Device Sequence Number1
Product Code DTL
UDI-Device Identifier08717648013980
UDI-Public08717648013980
Combination Product (y/n)N
Reporter Country CodeCH
PMA/PMN Number
K991102
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial
Report Date 11/16/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number1003330
Device Lot Number60453060
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 11/02/2023
Initial Date FDA Received11/16/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured04/13/2023
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-