Model Number 1973-03
Device Problem Entrapment of Device (1212)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 10/25/2023
Event Type  malfunction  
Event Description
It was reported that guidewire entrapment occurred.A 4.0 x 150mm, 90cm ranger global dcb otw balloon was selected for an endovascular therapy (evt) procedure in 90% stenosed moderately tortuous anatomy with mild calcification.A non-boston scientific (bsc) guidewire was used in the procedure.Per physician comment, the patient had become aggressive while inserting the device causing the shaft to kink and the wire to become entrapped in the device.Both device and guidewire had to be removed together.There were no patient complications, and the case was completed with a different device of the same model.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RANGER PACLITAXEL-COATED PTA BALLOON CATHETER
Type of Device
DRUG-ELUTING PERIPHERAL TRANSLUMINAL ANGIOPLASTY CATHETER
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
HEMOTEQ AG
adenauerstrasse 15
wuerselen 52146
GM   52146
Manufacturer Contact
rachel shields
4100 hamline ave n
arden hills, MN 55112
6512422111
MDR Report Key18181205
MDR Text Key328626396
Report Number2124215-2023-64646
Device Sequence Number1
Product Code ONU
UDI-Device Identifier08714729975878
UDI-Public08714729975878
Combination Product (y/n)Y
Reporter Country CodeJA
PMA/PMN Number
P190019
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Foreign,Health Professional,Company Representative,Distributor
Reporter Occupation Physician
Type of Report Initial
Report Date 11/21/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number1973-03
Device Catalogue Number1973-03
Device Lot Number04329H23
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 10/26/2023
Initial Date FDA Received11/21/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured05/12/2023
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-