Catalog Number NPFS02080
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Impaired Healing (2378); Fluid Discharge (2686)
Event Date 11/25/2022
Event Type  Injury  
Manufacturer Narrative
Internal reference number: (b)(4) h10: this complaint was opened by smith+nephew to document a patient complication identified through a review of clinical evidence from literature sources that includes reference to the use of a smith+nephew product.The reported issue(s) relate to known inherent procedural risks that are appropriately documented in our risk files.Smith+nephew will continue to monitor trends in accordance with our post-market surveillance process and take necessary action as required if anticipated severity and/or occurrence rates are exceeded.Smith+nephew has no reason to suspect that the product failed to meet any specifications at the time of manufacture.Based on our review of all currently available information, we are unable to confirm a relationship between the reported event and the device or identify a definitive root cause.However, as the use of our product cannot be excluded as a potential cause or contributory factor to the reported issue, we are conservatively submitting this report in accordance with applicable regulations.If additional information becomes available that alters the conclusions of this report, a follow-up report will be submitted as required.Turan, k., camurcu, y., kezer, m.Et al.Preliminary outcomes of kinematically aligned robot-assisted total knee arthroplasty with patient-specific cartilage thickness measurement.J robotic surg 17, 979¿985 (2023).(b)(6).
 
Event Description
It was reported that on literature review "preliminary outcomes of kinematically aligned robot-assisted total knee arthroplasty with patient-specific cartilage thickness measurement", after three (3) tka procedures assisted with navio system, patients had prolonged wound drainage and healing.In these patients, low-molecular-weight heparin was stopped (prophylaxis continued with acetylsalicylic acid) and an antibiotic treatment was started.Patients¿ outcome is unknown.No further information is available.
 
Manufacturer Narrative
Internal complaint reference number: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NAVIO SURGICAL SYSTEM TR
Type of Device
ORTHOPEDIC STEREOTAXIC INSTRUMENT
Manufacturer (Section D)
BLUE BELT TECHNOLOGIES
2905 northwest blvd ste 40
plymouth MN 55441
Manufacturer (Section G)
BLUE BELT TECHNOLOGIES
2905 northwest blvd ste 40
plymouth MN 55441
Manufacturer Contact
holly topping
7000 west william cannon drive
austin, TX 78735
5123913905
MDR Report Key18187175
MDR Text Key328716359
Report Number3010266064-2023-00206
Device Sequence Number1
Product Code OLO
UDI-Device Identifier00885556633052
UDI-Public885556633052
Combination Product (y/n)N
Reporter Country CodeTU
PMA/PMN Number
K152574
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Foreign,Literature
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 01/09/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Catalogue NumberNPFS02080
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 11/21/2023
Initial Date FDA Received11/21/2023
Supplement Dates Manufacturer Received01/02/2024
Supplement Dates FDA Received01/09/2024
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Unknown
Patient Sequence Number1
Patient Outcome(s) Other;
-
-