C.R. BARD, INC. (BASD) -3006260740 POWERPORT ISP M.R.I. IMPLANTABLE PORT, GROSHONG SINGLE-LUMEN, 8F; PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVASCULAR
|
Back to Search Results |
|
Catalog Number 9808560 |
Device Problems
Fracture (1260); Material Separation (1562); Improper or Incorrect Procedure or Method (2017); Deformation Due to Compressive Stress (2889); Naturally Worn (2988)
|
Patient Problem
No Clinical Signs, Symptoms or Conditions (4582)
|
Event Date 11/13/2023 |
Event Type
malfunction
|
Event Description
|
It was reported that approximately four years after port placement, the catheter was allegedly broken.Reportedly, the port was removed and replaced.There was no reported patient injury.
|
|
Manufacturer Narrative
|
H10: as the lot number for the device was not provided, a review of the device history records could not be performed.The return of the sample is pending.The investigation of the reported event is currently underway.H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : device pending return.
|
|
Event Description
|
It was reported that approximately four years after port placement, the catheter was allegedly broken.Reportedly, the port was removed and replaced.There was no reported patient injury.
|
|
Manufacturer Narrative
|
H10: manufacturing review: a manufacturing review was not requested as the lot number reported is unknown.Investigation summary: one powerport isp mri implantable port attached to a groshong catheter in two segments was returned for evaluation.Visual, microscopic, functional and tactile evaluations were performed on the returned device.A complete circumferential break was noted on the distal end of the attached catheter and on the proximal end of the distal catheter segment.The edges of the complete circumferential breaks were noted to be uneven and the surfaces were noted to be round and smooth on one region and granular in the other region.Therefore the investigation is confirmed for the reported fracture and the identified material separation, deformation and material wear issues.The investigation is also confirmed for the identified improper procedure issue as the port was used after four years with no regular flushing.The definitive root cause for the identified improper procedure issue is use related.It is unknown whether patient and/or procedural issues contributed to the reported event.Labeling review: a review of product labeling documentation (e.G., procedural instructions, indications, warnings, precautions, cautions, possible complications, contraindications, nursing guide, and unit label) did not find any product labeling inadequacy.The instruction for use states that flushing volumes: when port not in use- 5 ml heparinized saline every 4 weeks.H10: g3, h6 (device) h11: h6 (method, result, conclusion) h11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : see h10.
|
|