Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
Information was received from a healthcare professional via a manufacturer representative regarding a patient with spinal therapy.P reoperative diagnosis of this surgery was primary osteoporosis.Type of fracture was intraspinal cleft.Level at which the implant performed was l1.Procedure or therapy performed was percutaneous vertebroplasty.It was reported that during balloon dilation of l1 right side entry, the pathway was created by aiming to fill the cleft with a cavity (cancellous bone) according to the procedure manual.Along with the inflation of the balloon, the balloon entered the cleft and the balloon ruptured.The contrast agent leaked into the vertebral body; the contrast agent was collected into the vertebral body using an inflation syringe.The physician's opinion is that the boundary with the cleft was bone sclerosis, so it stuck into the balloon like a knife and broke the balloon.The rupture occurred at an expansion capacity of approximately 2.5 and extended pressure 260psi.Subsequently, treatment was performed with a replacement product and cementing was completed as per normal procedure.No fragment of the balloon remaining in the patient's body.There was no patient symptoms or complications as a result of this event.
|