• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION REZUM; UNIT, ELECTROSURGICAL ENDOSCOPIC (WITH OR WITHOUT ACCESSORIES)

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION REZUM; UNIT, ELECTROSURGICAL ENDOSCOPIC (WITH OR WITHOUT ACCESSORIES) Back to Search Results
Model Number D2201
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Hematoma (1884); Hemorrhage/Bleeding (1888); Pain (1994); Urinary Tract Infection (2120); Urinary Incontinence (4572); Swelling/ Edema (4577)
Event Date 12/13/2023
Event Type  Injury  
Event Description
It was reported that after a water vapor therapy procedure, the patient lost all the prostate tissue, and also reports pain, edema, bleeding/hematoma, hyperactive bladder, and infection of the urinary system.The patient also needed a medical intervention in a hyperbaric chamber with medications for the hyperactive bladder.He was on a catheter for one month.The issue is ongoing.
 
Event Description
It was reported that after a water vapor therapy procedure, the patient lost all the prostate tissue, and also reports pain, edema, bleeding/hematoma, hyperactive bladder, and infection of the urinary system.The patient also needed a medical intervention in a hyperbaric chamber with medications for the hyperactive bladder.He was on a catheter for one month.The issue is ongoing.
 
Manufacturer Narrative
There was no device available for analysis; therefore, no physical or visual analysis of the product could be performed.The reported patient symptoms are a known risk associated with implant of these devices as indicated in the instructions for use.Based on the information available, a conclusion code of known inherent risk of device was assigned to this investigation.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
REZUM
Type of Device
UNIT, ELECTROSURGICAL ENDOSCOPIC (WITH OR WITHOUT ACCESSORIES)
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer Contact
farshad fahimi
4100 hamline avenue north
building c
saint paul, MN 55112
MDR Report Key18432642
MDR Text Key331820501
Report Number2124215-2023-74719
Device Sequence Number1
Product Code KNS
Combination Product (y/n)N
Reporter Country CodePE
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Foreign,Health Professional
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 01/16/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Model NumberD2201
Device Catalogue NumberD2201
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 12/13/2023
Initial Date FDA Received01/02/2024
Supplement Dates Manufacturer Received01/04/2024
Supplement Dates FDA Received01/16/2024
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other;
Patient Age63 YR
Patient SexMale
-
-