INTUITIVE SURGICAL, INC DAVINCI XI; PATIENT SIDE CART, 4-ARM Back to Search Results
Model Number 380652-41
Device Problem Insufficient Information (3190)
Patient Problem Hemorrhage/Bleeding (1888)
Event Date 12/08/2023
Event Type  Injury  
Event Description
It was reported that during a da vinci assisted lower anterior resection, the procedure was converted to open due to bleeding.The cause of the bleeding is unknown at this time.
 
Manufacturer Narrative
No intuitive surgical, inc.(isi) product has been implicated or returned for failure analysis (fa).Advanced energy logs show the vessel sealer extend (vse) instrument was installed twice and passed homing each time.There were 55 cut complete events with no errors.E100 logs show 1 coagulation event with no errors.84 seal events were recorded, with 1 high initial starting impedance error.A system log review did not reveal any system errors that would have caused or contributed to the reported event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DAVINCI XI
Type of Device
PATIENT SIDE CART, 4-ARM
Manufacturer (Section D)
INTUITIVE SURGICAL, INC
3410 central expressway
santa clara CA
Manufacturer (Section G)
INTUITIVE SURGICAL, INC
3410 central expressway
santa clara CA
Manufacturer Contact
izabel nielson
3410 central expressway
santa clara, CA 
4085232100
MDR Report Key18449152
MDR Text Key332162653
Report Number2955842-2023-21856
Device Sequence Number1
Product Code NAY
UDI-Device Identifier00886874110720
UDI-Public(01)00886874110720
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K131861
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Company Representative
Reporter Occupation Non-Healthcare Professional
Remedial Action Other
Type of Report Initial
Report Date 12/08/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Model Number380652-41
Device Catalogue Number380652
Device Lot NumberN/A
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 12/08/2023
Initial Date FDA Received01/04/2024
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured06/21/2018
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Removal/Correction NumberN/A
Patient Sequence Number1
Treatment
DA VINCI INSTRUMENTS AND ACCESSORIES.
-
-