Model Number ENEW2424C80EE
Device Problems Leak/Splash (1354); Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Chest Pain (1776); Pleural Effusion (2010)
Event Date 01/28/2024
Event Type  Injury  
Manufacturer Narrative
Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Event Description
A valiant captivia stent graft and an endurant cuff were implanted during the endovascular treatment of a 200mm type b thoracic dissection.It was reported that during the index procedure the valiant captivia stent graft was implanted.The proximal end of the valiant captivia was positioned with the posterior edge of the lsa to deploy the stent.The distal end of the valiant captivia was implanted with an endurant cuff as a restrictive stent.Intraoperative angiography showed a type iv endoleak.Post theindex procedure, the patient complained of chest pain.A repeat ct showed the persistent type iv endoleak and that the patient has developed a pleural effusion.Per the physician the cause of the endoleak was due to internal leakage of the covered stent.No additional clinical sequalae were provided and the patient will be monitored.
 
Manufacturer Narrative
B5; additional information received: after the chest pain and pleural effusion occurred, the surgeon planned to implant a non mdt stent graft 11 days post the index procedure.During the second operation, an angiography performed found that the membrane leakage in the valiant captivia had since resolved.No intervention was therefore required.The type iv endoleak was not seen in the endurant stent graft.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Manufacturer Narrative
Film evaluation summary: the reported pleural effusion and chest pain could not be confirmed on the films provided, therefore, the cause could not be determined.B5; additional information received ; it was reported that no intervention was required to treat the pleural effusion as it was reab sorbed and the patient was discharged.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ENDURANT ILIAC STENT GRAFT
Type of Device
SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT
Manufacturer (Section D)
MEDTRONIC IRELAND
parkmore business park west
galway
EI 
Manufacturer (Section G)
MEDTRONIC IRELAND
parkmore business park west
galway
EI  
Manufacturer Contact
alison sweeney
parkmore business park west
galway 
EI  
091708096
MDR Report Key18614006
MDR Text Key334209113
Report Number9612164-2024-00537
Device Sequence Number1
Product Code MIH
Combination Product (y/n)N
Reporter Country CodeCH
PMA/PMN Number
P100021
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial,Followup,Followup
Report Date 02/20/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberENEW2424C80EE
Device Catalogue NumberENEW2424C80EE
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 01/28/2024
Initial Date FDA Received01/31/2024
Supplement Dates Manufacturer Received02/05/2024
02/15/2024
Supplement Dates FDA Received02/07/2024
02/20/2024
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured09/12/2023
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other;
Patient Age39 YR
Patient SexMale
Patient Weight90 KG
-
-