Model Number 39467-125
Device Problem Noise, Audible (3273)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 09/01/2023
Event Type  malfunction  
Manufacturer Narrative
B3 - date of event: date of event was approximated to 09/01/2023 as the exact event date was not reported.Device evaluated by mfr: the device was returned for evaluation.The advancer, handshake connections, sheath, coil, burr and annulus were visually and microscopically examined.Inspection found that the burr was detached, and that the coil was stretched and detached.Functional testing was performed by attempting to rotate the drive shaft, and the drive shaft was able to be rotated.The rotapro advancer was then connected to the rotapro control console system.The advancer was able to reach optimum speed without stalling.During functional testing there was no abnormalities to the device, and it ran with no speed or noise issues.The advancer was able to reach optimum speed without abnormal noises during analysis.As the burr and coil were found to be damaged, it was considered likely that the abnormal noises heard during the procedure were attributable to the separation of the coil from the burr.No other issues were identified during the product analysis.
 
Event Description
Reportable based on device analysis completed on 16jan2024.It was reported that the burr sounded abnormal.A 1.25mm rotapro was selected for use.During platform testing, it was noted that the burr did not sound right.The procedure was completed with another of the same device.No patient complications were reported.However, device analysis revealed that the burr and coil were detached.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ROTAPRO
Type of Device
CATHETER, CORONARY, ATHERECTOMY
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
model farm road
cork T12 Y K88
EI   T12 YK88
Manufacturer Contact
rachel shields
4100 hamline ave n
arden hills, MN 55112
6512422111
MDR Report Key18627503
MDR Text Key334389595
Report Number2124215-2024-02277
Device Sequence Number1
Product Code MCX
UDI-Device Identifier08714729893356
UDI-Public8714729893356
Combination Product (y/n)N
Reporter Country CodeUS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional,Company Representative
Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date 02/01/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number39467-125
Device Catalogue Number39467-125
Device Lot Number0030630775
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/21/2023
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 01/16/2024
Initial Date FDA Received02/01/2024
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured12/01/2022
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-