Model Number DB-2202-45
Device Problem Defective Device (2588)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 11/16/2023
Event Type  malfunction  
Event Description
It was reported that a deep brain stimulation (dbs) lead contact was damaged during a permanent implant procedure.The procedure was successfully completed with an alternate device.The returned lead revealed that the distal array is fractured between electrode 1 and electrodes 2,3, and 4.There was no patient harm due to the reported event.
 
Manufacturer Narrative
The returned lead was analyzed and visual inspection revealed that the distal array is fractured between electrode 1 and electrodes 2,3, and 4.A product labeling review identified that the device was used per the instructions for use (ifu) product label and it did not reveal any anomalies.Based on all available information, the reported event of the lead damage was confirmed.The returned lead was analyzed and visual inspection revealed that the distal array is fractured between several lead electrodes.Therefore, with the reported observations and the labeling review, it has been determined that the probable cause was a manufacturing deficiency.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VERCISE CARTESIA
Type of Device
STIMULATOR, ELECTRICAL, IMPLANTED, FOR PARKINSONIAN SYMPTOMS
Manufacturer (Section D)
BOSTON SCIENTIFIC NEUROMODULATION
25155 rye canyon loop
valencia CA 91355
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
road 698, lot no. 12
dorado PR 00646 -260
*   00646-2602
Manufacturer Contact
erik sherburne
25155 rye canyon loop
valencia, CA 91355
7632920920
MDR Report Key18637149
MDR Text Key334837150
Report Number3006630150-2024-00443
Device Sequence Number1
Product Code NHL
Combination Product (y/n)N
Reporter Country CodeTU
PMA/PMN Number
P150031
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Foreign,Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial
Report Date 02/02/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberDB-2202-45
Device Catalogue NumberDB-2202-45
Device Lot Number7104120
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/14/2023
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 01/11/2024
Initial Date FDA Received02/03/2024
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured04/18/2023
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-