MAUDE Adverse Event Report: ARROW INTERNATIONAL LLC ARROW CVC SET: 2-LUMEN 7 FR X 20 CM; CATHETER PERCUTANEOUS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARROW INTERNATIONAL LLC ARROW CVC SET: 2-LUMEN 7 FR X 20 CM; CATHETER PERCUTANEOUS Back to Search Results
Catalog Number CV-17702-E
Device Problem Material Twisted/Bent (2981)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 01/24/2024
Event Type  malfunction  
Event Description
It was reported ", the swg was found kinked during used on the patient".No medical intervention required.The patient's current condition is reported as "fine".
 
Manufacturer Narrative
(b)(4).
 
Manufacturer Narrative
Qn# (b)(4).The customer provided one photo for analysis.The complaint of swg kinked was able to be confirmed by the photo.The customer also returned an opened cvc kit including one swg in its advancer, an arrow raulerson syringe (ars), and an 18ga introducer needle for evaluation.The guide wire was returned within the advancer tube.No obvious signs of use was observed.The guide wire was observed to have a one kink on the distal j-bend of the body.The distal j-bend was not misshapen and was intact.Microscopic examination confirmed the kink in the guide wire body.Both welds were present and were observed to be full and spherical.The kink in the guide wire was located 3 mm from the distal tip.The overall length of the guide wire measured 602 mm which is within the specification of 596-604 mm per guide wire product drawing.The outer diameter of the guide wire measured 0.805 mm which is within the specification of 0.788-0.826 mm per guide wire product drawing.The guide wire was advanced through the returned ars and 18ga introducer needle to functionally test the guide wire.The guide wire passed through both components with little to no resistance.Performed per the instructions for use (ifu) statement, "advance guidewire into arrow raulerson syringe approximately 10 cm until it passes through syringe valves or into introducer needle." a manual tug test confirmed that both the distal and proximal welds were intact.A device history record review was performed, and no relevant findings were identified.The ifu provided with the kit describes suggested techniques to minimize the likelihood of guide wire damage during use.The instructions caution, "do not apply excessive force in placing or removing catheter or guidewire.Excessive force can cause component damage or breakage.If damage is suspected or withdrawal cannot be easily accomplished, radiographic visualization should be obtained and further consultation requested." the report that the guide wire kinked during use was confirmed through examination of the returned sample.The guide wire had one kink on the distal j-bend.The returned guide wire met all relevant dimensional/ functional requirements, and a device history record review did not identify any manufacturing related issues.Based on the condition of the guide wire and the report that the damage was observed during use, unintentional use error caused or contributed to this event.Teleflex will continue to monitor and trend for reports of this nature.
 
Event Description
It was reported ", the swg was found kinked during used on the patient".No medical intervention required.The patient's current condition is reported as "fine.".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ARROW CVC SET: 2-LUMEN 7 FR X 20 CM
Type of Device
CATHETER PERCUTANEOUS
Manufacturer (Section D)
ARROW INTERNATIONAL LLC
morrisville NC
Manufacturer (Section G)
ARROW INTERNATIONAL CR, A.S.
jamska 2359/47
zdar nad sazavou 591 0 1
EZ   591 01
Manufacturer Contact
katharine tarpley
3015 carrington mill blvd
morrisville, NC 27560
MDR Report Key18710336
MDR Text Key335444962
Report Number3006425876-2024-00205
Device Sequence Number1
Product Code DQY
Combination Product (y/n)N
Reporter Country CodeCH
PMA/PMN Number
K862056
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,User Facility,Company Representative,Distributor
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 01/24/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Catalogue NumberCV-17702-E
Device Lot Number71F22J2628
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/05/2024
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 01/24/2024
Initial Date FDA Received02/15/2024
Supplement Dates Manufacturer Received02/23/2024
Supplement Dates FDA Received02/26/2024
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured09/26/2022
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Treatment
NONE REPORTED; NONE REPORTED
-
-