• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BECTON DICKINSON INFUSION THERAPY SYSTEMS INC. BD INSYTE AUTOG BC BLU 22GA X 1.0IN; INTRAVASCULAR CATHETER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BECTON DICKINSON INFUSION THERAPY SYSTEMS INC. BD INSYTE AUTOG BC BLU 22GA X 1.0IN; INTRAVASCULAR CATHETER Back to Search Results
Catalog Number 382523
Device Problem Retraction Problem (1536)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 02/07/2024
Event Type  malfunction  
Event Description
It was reported that a bd insyte autog bc blu 22ga x 1.0in needle did not retract.The following information was provided by the initial reporter: button to retract needle not engaging when pressed.
 
Manufacturer Narrative
H.3.A device evaluation and/or device history review is anticipated but is not complete.Upon completion, a supplemental report will be filed.
 
Event Description
No additional information.
 
Manufacturer Narrative
No photos or physical samples that display the reported condition were available for investigation.A device history record review was completed by our quality engineer team for provided material number 382523 and lot number 3284646.The review did not reveal any detected abnormalities during the production process that could have contributed to this defect and all quality tests were found to be within specification.Based on the available information, an exact cause for this incident could not be identified.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD INSYTE AUTOG BC BLU 22GA X 1.0IN
Type of Device
INTRAVASCULAR CATHETER
Manufacturer (Section D)
BECTON DICKINSON INFUSION THERAPY SYSTEMS INC.
9450 south state street
sandy UT 84070
Manufacturer (Section G)
BECTON DICKINSON INFUSION THERAPY SYSTEMS INC.
9450 south state street
sandy UT 84070
Manufacturer Contact
helen cox (mdr)
75 north fairway drive
vernon hills, IL 60061
8473935694
MDR Report Key18759868
MDR Text Key336962606
Report Number1710034-2024-00126
Device Sequence Number1
Product Code FOZ
UDI-Device Identifier00382903825233
UDI-Public(01)00382903825233
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K201075
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type User Facility
Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date 03/05/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Catalogue Number382523
Device Lot Number3284646
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 02/08/2024
Initial Date FDA Received02/22/2024
Supplement Dates Manufacturer Received03/05/2024
Supplement Dates FDA Received03/25/2024
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured10/12/2023
Is the Device Single Use? Yes
Type of Device Usage Initial
Patient Sequence Number1
-
-