MAUDE Adverse Event Report: CARDINAL HEALTH SANTA CLARA MYNX CONTROL; DEVICE, HEMOSTASIS, VASCULAR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

CARDINAL HEALTH SANTA CLARA MYNX CONTROL; DEVICE, HEMOSTASIS, VASCULAR Back to Search Results
Catalog Number MX5060E
Device Problem Premature Activation (1484)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 11/23/2023
Event Type  malfunction  
Manufacturer Narrative
As reported, when using a 5f mynx control vascular closure device (vcd), the sealant protection tip remains damaged.There was no reported patient injury.The device was used in a transfemoral cerebral angiogram.Additional information was requested but not provided.A non-sterile ¿mynx control vascular closure device 5f¿ involved in the reported complaint was returned for investigation.Visual inspection of the received device showed that button 1 and button 2 were not depressed with the stopcock closed.No damage was observed in the atraumatic tip of the returned device.The sealant was noted swelled from exposure to blood and partially exposed from the sealant sleeves, which were observed to be kinked/bent as received; however, no cracks were observed on it.The syringe was received separated from the device, and the procedural sheath was not returned.Dimensional analysis could not be performed on the returned device due to the severely kinked/bent sealant sleeve assembly condition.Per functional analysis, a simulated deployment test was performed on the returned device per the mynx control instructions for use (ifu), step 2: deploy sealant.Button 1 was able to be depressed to deploy the sealant with no resistance felt.No issues were noted with respect to button 1 deployment during the device failure investigation.The returned device performed as intended per the mynx control ifu.Button #2 was able to be fully depressed, and no issues were noted with respect to button 2.Per microscopic analysis, visual inspection at high magnification showed that the sealant sleeves were kinked/bent as received with no cracks observed on it.In addition, the sealant was noted to be swelled from exposure to blood and partially exposed from the sealant sleeves.The reported event of ¿sealant sleeves (cartridge assembly)-kinked/bent¿ was confirmed through analysis of the returned device as the sleeves were found to be severely kinked/bent as received.Additionally, a condition was noted in the returned device of ¿mynx control system-deployment difficulty-premature¿ due to the partially exposed sealant from the kinked sleeves.The exact cause of the observed conditions could not be conclusively determined during analysis.Based on the limited information available for review and product analysis, it is difficult to determine what factors may have contributed to the issue experienced.However, procedural/handling factors (such as excessive force during insertion and/or incorrect insertion angle), and/or the condition of the sheath (although not returned) possibly contributed to the kinked condition of the sealant sleeves, and the subsequent premature exposure of the sealant.It should be noted that the mynx control device is manufactured with a slit at the end of the catheter cartridge tubing.The outer sleeve is assembled with 2 side slit overlapping outer sleeves.The sealant is placed right under the outer sleeve assembly and is protected from exposing prematurely.The slits on the outer sleeve assembly are designed to decrease unsheathing force and increase deployment reliability.Refer to the diagram of the mynx control vcd within the ifu displaying the sealant sleeve with slit.If the outer sleeve is damaged/kinked during prepping phase and/or insertion into sheath, it could cause the sealant to be exposed/swollen prematurely and/or obstruct the device path and prevent the device from being inserted into the procedural sheath.As warned in the ifu, which is not intended as a mitigation, ¿do not use if components or packaging appear to be damaged or defective or if any portion of the packaging has been previously opened.¿ additionally, the ifu states ¿step 1: position balloon, insert the mynx control vcd into the procedural sheath through the sheath valve.Advance the catheter until the sheath catch nears the hub of the sheath.Rotate the sheath catch as needed to hook onto the side port of the procedural sheath.¿ neither the product analysis, nor the information available for review suggest that the failures noted could be related to the design or manufacturing process of the unit.Therefore, no corrective/preventative actions will be taken at this time.
 
Event Description
As reported, when using a 5f mynx control vascular closure device (vcd), the sealant protection tip remains damaged.There was no reported patient injury.The device was used in a transfemoral cerebral angiogram.Additional information was requested but not provided.The device is being returned for evaluation.Addendum: product evaluation shows the sealant was partially exposed from the sealant sleeves as the sleeves were kinked/bent.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MYNX CONTROL
Type of Device
DEVICE, HEMOSTASIS, VASCULAR
Manufacturer (Section D)
CARDINAL HEALTH SANTA CLARA
5452 betsy ross drive
santa clara 95054
Manufacturer (Section G)
CORDIS US CORP.
14201 nw 60 avenue
miami lakes FL 33014
Manufacturer Contact
karla castro
5452 betsy ross drive
santa clara, CA 95054
7863138372
MDR Report Key18825807
MDR Text Key337740959
Report Number3004939290-2024-00098
Device Sequence Number1
Product Code MGB
Combination Product (y/n)N
Reporter Country CodeKS
PMA/PMN Number
P040044
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative
Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date 03/04/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue NumberMX5060E
Device Lot NumberF2316601
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/22/2023
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 02/16/2024
Initial Date FDA Received03/04/2024
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured07/01/2023
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient EthnicityNon Hispanic
Patient RaceAsian
-
-