Lot Number 0032304799
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem Nerve Damage (1979)
Event Date 02/08/2024
Event Type  Injury  
Manufacturer Narrative
It was indicated that the device will not be returned for evaluation.If there is any further relevant information obtained, a supplemental medwatch will be filed.
 
Event Description
During an atrial fibrillation a polarx catheter was selected for use.A c-map was evaluated before moving to the right inferior pulmonary vein and it was not really strong.The recorder had to gain up all the way to max and the phrenic stim was still not very strong, but it was decided to ablate.The catheter was placed, and the freeze was started.Upon phrenic and the physician had it, but it wasn't very strong.At almost the 2-minute mark the phrenic just bottomed out and stopped.A double stopped was preformed immediately on ablation.The catheters were moved around trying to regain the phrenic back and medication was administered.The phrenic did not return and the procedure was cancelled.The patient was taken to post op with phrenic nerve palsy.The device is not expected for return due to disposal.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
POLARX
Type of Device
CATHETER, PERCUTANEOUS, CARDIAC ABLATION, FOR TREATMENT OF ATRIAL FIBRILLATION
Manufacturer (Section D)
BOSTON SCIENTIFIC DE COSTA RICA S.R.L.
302 parkway
global park, la aurora
heredia
CS 
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
302 parkway, global park
la aurora - heredia
CS  
Manufacturer Contact
timothy degroot
4100 hamline avenue north
dc a330
saint paul, MN 55112
6515826168
MDR Report Key18847354
MDR Text Key337017768
Report Number2124215-2024-13135
Device Sequence Number1
Product Code OAE
Combination Product (y/n)N
Reporter Country CodeUS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial
Report Date 03/06/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Lot Number0032304799
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 02/08/2024
Initial Date FDA Received03/06/2024
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured08/28/2023
Is the Device Single Use? Yes
Type of Device Usage Unknown
Patient Sequence Number1
Patient Outcome(s) Other;
Patient Age71 YR
Patient SexFemale
-
-