Model Number BML-V242QR-30
Device Problem Material Deformation (2976)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 02/29/2024
Event Type  Injury  
Manufacturer Narrative
The device was returned and the evaluation is ongoing.Should additional relevant information become available, a supplemental report will be submitted.
 
Event Description
It was reported that during a therapeutic endoscopic, retrograde cholangiopancreatography (ercp) case, the single use mechanical lithotriptor, was used to grasp the stone and the coil sheath was crushed and deformed.As such, the stone could not be destroyed.Therefore, non-olympus device was used to incarcerate and break the stone.The wire was removed, and a tube stent was inserted, and procedure was completed.There was no health hazard to the patient.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SINGLE USE MECHANICAL LITHOTRIPTOR V
Type of Device
SINGLE USE MECHANICAL LITHOTRIPTOR
Manufacturer (Section D)
AOMORI OLYMPUS CO., LTD.
2-248-1 okkonoki
kuroishi-shi, aomori 036-0 357
JA  036-0357
Manufacturer (Section G)
AOMORI OLYMPUS CO., LTD.
2-248-1 okkonoki
kuroishi-shi, aomori 036-0 357
JA   036-0357
Manufacturer Contact
todd brill
800 west park drive
westborough, MA 01581
5082077661
MDR Report Key18862009
MDR Text Key337185383
Report Number9614641-2024-00614
Device Sequence Number1
Product Code LQC
UDI-Device Identifier04953170218392
UDI-Public04953170218392
Combination Product (y/n)N
Reporter Country CodeJA
PMA/PMN Number
CLASS2-EXMPT
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Foreign,Health Professional,User Facility,Company Representative
Reporter Occupation Physician
Type of Report Initial
Report Date 03/07/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberBML-V242QR-30
Device Lot Number2ZK
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/06/2024
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 02/29/2024
Initial Date FDA Received03/07/2024
Was Device Evaluated by Manufacturer? No
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Treatment
LITHOTRIPTOR HANDLE, BML-110A-1, SN-UNK; MECHANICAL LITHOTRIPTOR MAJ-441, SN-UNK; VANBECK HANDLE, MODEL#-UNK, SN-UNK
Patient Outcome(s) Required Intervention;
-
-