Catalog Number 8065751761
Device Problem Appropriate Term/Code Not Available (3191)
Patient Problems Corneal Scar (1793); Eye Burn (2523)
Event Date 02/21/2024
Event Type  Injury  
Manufacturer Narrative
Investigation including root cause analysis is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.The manufacturer internal reference number is: (b)(4).
 
Event Description
A customer reported that an ophthalmic operating hand piece was used for the cataract surgery which was found to be clogged and milky white substance was discharged during the surgery and patient experienced the wound burn and mild car was on stye.The patient was treated with bandage.The surgery was completed on the same day.Current patient condition was recovering.
 
Manufacturer Narrative
The product under investigation is not a serviceable device.Therefore, a service record review was not performed.However, the hp was returned for testing on this investigation.A non-conformance based review of the serial number was performed and did not reveal any potential contributing factors to the reported complaint.A manufacturing device history record (dhr) review was performed prior to product release to ensure that the product was manufactured in compliance with the device master record.Based on the assessment, the product met release criteria.A review for complaints reported against this serial number was performed.No similar complaints were reported for the product serial under investigation.The hp was received for testing on this investigation.A visual assessment of the returned sample revealed no obvious nonconformity.The handpiece was connected to a calibrated resistance test box, where the input and output impedance, resistance, and dissipation were found to be within specifications.A flow rate test was performed on the irrigation and aspiration lines of the handpiece which found the handpiece to meet specifications.The returned handpiece was connected to a calibrated system.The handpiece tuned successfully and completed a five-minute burn-in test with the system set at 100% ultrasonic torsional power.The handpiece was connected to dynamic tuning fixture (dtf) for stroke length testing on the longitudinal and torsional movements which found the handpiece to meet specification.The handpiece was found to meet specifications.Therefore, the root cause of the reported event is inconclusive.Manufacturer will continue to monitor data for evidence of adverse trending and take further action, as appropriate.The manufacturer internal reference number is: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CENTURION VISION SYSTEM, ACCESSORY, OZIL TORSIONAL HANDPIECE
Type of Device
UNIT, PHACOFRAGMENTATION
Manufacturer (Section D)
ALCON RESEARCH, LLC - IRVINE TECHNOLOGY CENTER
15800 alton parkway
irvine CA 92618
Manufacturer (Section G)
ALCON RESEARCH, LLC - IRVINE TECHNOLOGY CENTER
15800 alton parkway
irvine CA 92618
Manufacturer Contact
jonathan schlech
6201 south freeway
mail stop ab2-6
fort worth, TX 76134
8007579780
MDR Report Key18985080
MDR Text Key338660331
Report Number2028159-2024-00472
Device Sequence Number1
Product Code HQC
UDI-Device Identifier00380657517619
UDI-Public00380657517619
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K121555
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Company Representative
Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date 05/29/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Catalogue Number8065751761
Device Lot Number13NE6Y
Was Device Available for Evaluation? Device Returned to Manufacturer
Initial Date Manufacturer Received 02/28/2024
Initial Date FDA Received03/27/2024
Supplement Dates Manufacturer Received09/02/2015
Supplement Dates FDA Received05/29/2024
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured10/14/2020
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
Patient Outcome(s) Other; Required Intervention;
Patient Age58 YR
-
-