Catalog Number 4824062
Device Problem Insufficient Information (3190)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 03/04/2024
Event Type  malfunction  
Manufacturer Narrative
Investigation: the run data file (rdf) was analyzed for this event.The analysis of the run data file did not identify a conclusive root cause for the presence of air in the donor/return lines for this procedure.No unusual process variable was identified and the signals in the run data file indicate that the trima accel system operated as intended.Specifically, the pressure signals and the pumped volume values were all within the expected ranges during tubing set test, ac prime, and blood prime states of the procedure.A review of the device history record (dhr) for this lot showed no irregularities during manufacturing that were relevant to this issue.The customer history report indicates there were twelve reports of a similar issue.A disposable complaint history search was performed for this lot and found one other report for similar issue on this lot, from the same customer.Investigation is in process.A follow-up report will be provided.
 
Event Description
The customer reported that during an allogenic platelet procedure on a trima device a small air bubble, approximately 1/8th inch, was seen in the line going back to the donor during the first return.The operator clamped the line before air was returned to the donor.No medical intervention was reported, and the patient is reported as stable and release home.Full donor id #: (b)(6) the customer reported that all luer connections were tight and there was no clotting in the channel or reservoir.The blood diversion pouch was not inflated with air and the donor was not connected prior to ac prime.The customer stated that no air was being drawn in through the ac line or filter.The platelet collection set is not available for return because it was discarded by the customer.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TRIMA ACCEL
Type of Device
TRIMA ACCEL PLATELET, PLASMA, RBC SET
Manufacturer (Section D)
TERUMO BCT
lakewood CO 80215
Manufacturer (Section G)
TERUMO BCT
10810 w. collins ave
lakewood CO 80215
Manufacturer Contact
scot hilden
10810 w. collins ave
lakewood, CO 80215
MDR Report Key18990530
MDR Text Key339035662
Report Number1722028-2024-00107
Device Sequence Number1
Product Code GKT
UDI-Device Identifier05020583824065
UDI-Public05020583824065
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
BK190332
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional
Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date 03/28/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number4824062
Device Lot Number2303161142
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 03/05/2024
Initial Date FDA Received03/28/2024
Was Device Evaluated by Manufacturer? No
Date Device Manufactured03/16/2023
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other;
Patient Age29 YR
Patient SexMale
-
-