Model Number 1000-D
Device Problem Failure to Interrogate (1332)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 03/05/2024
Event Type  malfunction  
Manufacturer Narrative
Livanova usa, inc.Submits this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation, based on information that livanova has obtained, but may not have been able to investigate or verify prior to the date the report was required by the fda.This report does not constitute an admission, or a conclusion by fda or anyone else, that the device, livanova, or livanova's employees caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any "defects¿ or "malfunctions¿.These words are incorporated into the fda 3500a medwatch form by the fda, and livanova objects to their use.
 
Event Description
It was reported that generator intended to be implanted in the patient was unable to be interrogated.Troubleshooting was attempted, efforts were made to reduce emi, however the generator was still unable to be interrogated after several attempts.The surgeon opted to implant a different generator which was implanted and successfully interrogated.Device history records were reviewed and the device was seen to pass all functional and quality testing prior to distribution.The device has been received into product analysis.No other relevant information has been received to date.
 
Manufacturer Narrative
H6 investigation findings; corrected data; initial mdr inadvertently entered incorrect code.
 
Event Description
Product analysis was completed and it was discovered that the device was likely exposed to electrocautery causing a premature depletion of the battery.No other relevant information has been received to date.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PULSE GEN MODEL 1000-D
Type of Device
GENERATOR
Manufacturer (Section D)
LIVANOVA USA, INC.
100 cyberonics blvd
houston TX 77058
Manufacturer (Section G)
LIVANOVA USA, INC.
100 cyberonics blvd
suite 600
houston TX 77058
Manufacturer Contact
cindy scott
100 cyberonics blvd
suite 600
houston, TX 77058
2816672681
MDR Report Key19004338
MDR Text Key338913839
Report Number1644487-2024-00360
Device Sequence Number1
Product Code LYJ
UDI-Device Identifier05425025750528
UDI-Public05425025750528
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P970003
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 04/23/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number1000-D
Device Lot Number853
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/15/2024
Is the Reporter a Health Professional? Yes
Event Location Other
Initial Date Manufacturer Received 03/05/2024
Initial Date FDA Received03/29/2024
Supplement Dates Manufacturer Received04/23/2023
Supplement Dates FDA Received04/23/2024
Was Device Evaluated by Manufacturer? No
Date Device Manufactured09/18/2023
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Age65 YR
Patient SexMale
-
-