• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION INGEVITY+; DRUG ELUTING PERMANENT RIGHT VENTRICULAR OR ATRIAL PACEMAKER ELECTRODES

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION INGEVITY+; DRUG ELUTING PERMANENT RIGHT VENTRICULAR OR ATRIAL PACEMAKER ELECTRODES Back to Search Results
Model Number 7842
Device Problems Off-Label Use (1494); Device Sensing Problem (2917); Material Integrity Problem (2978)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 03/25/2024
Event Type  malfunction  
Event Description
It was reported that during the procedure, when this right ventricular (rv) lead was fixed in the left bundle branch area, the lead exhibited unsatisfactory parameters (not specified).The physician tried three different times to position the lead in order to obtain satisfactory measurements; however, this was unsuccessful.The lead was removed from the patient.The physician attempted to clean the helix mechanism; however, observed it to be damaged due to the multiple attempts to position the lead.Subsequently, the lead was exchanged for a new one to complete the procedure and the lead parameters were satisfactory.No adverse patient effects were reported.This lead is expected for return.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INGEVITY+
Type of Device
DRUG ELUTING PERMANENT RIGHT VENTRICULAR OR ATRIAL PACEMAKER ELECTRODES
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
4100 hamline avenue north
saint paul MN 55112
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
road 698, lot no. 12
dorado PR 00646 -260
*   00646-2602
Manufacturer Contact
timothy degroot
4100 hamline avenue north
saint paul, MN 55112
6515826168
MDR Report Key19100088
MDR Text Key340455752
Report Number2124215-2024-22433
Device Sequence Number1
Product Code NVN
Combination Product (y/n)N
Reporter Country CodeIN
PMA/PMN Number
P150012/S083
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional
Reporter Occupation Physician
Type of Report Initial
Report Date 04/12/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number7842
Device Catalogue Number7842
Device Lot Number1294434
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 03/26/2024
Initial Date FDA Received04/12/2024
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured01/19/2024
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient SexFemale
-
-