W. L. GORE & ASSOCIATES, INC. GORE® TAG® CONFORMABLE THORACIC STENT GRAFT WITH ACTIVE CONTROL SYSTEM; SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT
|
Back to Search Results |
|
Catalog Number TGMR404015J |
Device Problem
Adverse Event Without Identified Device or Use Problem (2993)
|
Patient Problem
Disseminated Intravascular Coagulation (DIC) (1813)
|
Event Date 04/04/2024 |
Event Type
Injury
|
Event Description
|
The following information was reported to gore: on (b)(6) 2024, a patient underwent endovascular treatment of a chronic type b aortic dissection using two gore® tag® conformable thoracic stent graft with active control system (ctagac) devices.During the treatment, tgmr404015j was implanted just below the left subclavian artery.An angiography revealed a possible proximal type i endoleak.The physician decided to monitor it.The patient tolerated the procedure.On (b)(6) 2024, a disseminated intravascular coagulation (dic) was observed and a computed tomography angiography revealed a possible proximal type i endoleak.On (b)(6) 2024, a reintervention was performed.An angiography revealed no proximal type i endoleak, however additionally gore® tag® conformable thoracic stent graft with active control system (ctagac) was implanted proximally just below the left common carotid artery as planned.The patient tolerated the procedure.
|
|
Manufacturer Narrative
|
H3: code "other" was selected as the medical device remains implanted.Return not possible.W.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Blank fields present on this report include required fields and fields determined to be not applicable.Blank required fields indicate that the information was not provided, was deemed unavailable or was not applicable.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
|
|
Search Alerts/Recalls
|
|
|