MAUDE Adverse Event Report: ETHICON ENDO-SURGERY, LLC. HARMONIC ACE ADAPTIVE TISSUE TECHNOLOGY; INSTRUMENT, ULTRASONIC SURGICAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ETHICON ENDO-SURGERY, LLC. HARMONIC ACE ADAPTIVE TISSUE TECHNOLOGY; INSTRUMENT, ULTRASONIC SURGICAL Back to Search Results
Catalog Number HAR36
Device Problems Break (1069); Detachment Of Device Component (1104); Improper or Incorrect Procedure or Method (2017)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 03/28/2014
Event Type  malfunction  
Event Description
It was reported that during an procedure the first har36 was used but the blade sheared off.Second har36 was opened and changed the handpiece but still no resolution.Third har36 was opened to complete the procedure.No adverse event to the patient.Delay of 40 minutes.The user was trained.The product was stored according to labeling instructions.
 
Manufacturer Narrative
(b)(4).When additional information is received and/or the device analysis has been completed, a supplemental medwatch will be sent.
 
Manufacturer Narrative
(b)(4).The device was returned with the distal tip of the blade broken off and it was returned with the device.The remaining blade portion was scratched, evidence of contact with metal in or out of the operative field.The device was functionally tested with a generator.During functional testing on gen11 an alert screen was displayed.A probable cause of the device stop activating and display an alert screen is blade damage.Probable causes of blade damage, including breakage, are external contact during pre-op or general use, blade contact with other devices, staples or clips during the procedure or using any means other than the blade wrench to attach or detach the blade.Once minor blade damage has occurred, subsequent activations may increase damage severity and result in alert screens, such as ¿tighten assembly¿, ¿blade error detected¿ or "relaxed pressure on blade" followed by a ¿replace instrument¿ screen later in the procedure.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HARMONIC ACE ADAPTIVE TISSUE TECHNOLOGY
Type of Device
INSTRUMENT, ULTRASONIC SURGICAL
Manufacturer (Section D)
ETHICON ENDO-SURGERY, LLC.
475 calle c
guaynabo PR 0096 9
Manufacturer (Section G)
ETHICON ENDO-SURGERY, LLC
475 calle c
guaynabo PR 0096 9
Manufacturer Contact
guillermo villa
route 22 west po box 151
somerville, NJ 08876
9082180707
MDR Report Key3749013
MDR Text Key4483711
Report Number3005075853-2014-02550
Device Sequence Number1
Product Code LFL
Combination Product (y/n)N
Reporter Country CodeAS
PMA/PMN Number
K120729
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Company Representative
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 03/30/2014
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date09/25/2018
Device Catalogue NumberHAR36
Device Lot NumberUNKNOWN
Other Device ID NumberBATCH K92H42
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/22/2014
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 05/16/2014
Initial Date FDA Received04/14/2014
Supplement Dates Manufacturer ReceivedNot provided
Supplement Dates FDA Received05/19/2014
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured10/25/2013
Is the Device Single Use? Yes
Type of Device Usage Initial
Patient Sequence Number1
Treatment
GENERATOR, HANDPIECE
-
-