• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BARD PERIPHERAL VASCULAR, INC. MAXCORE DISPOSABLE CORE BIOPSY INSTRUMENTS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BARD PERIPHERAL VASCULAR, INC. MAXCORE DISPOSABLE CORE BIOPSY INSTRUMENTS Back to Search Results
Catalog Number MC1820
Device Problems Failure to Prime (1492); Self-Activation or Keying (1557); Positioning Problem (3009)
Patient Problems No Consequences Or Impact To Patient (2199); No Known Impact Or Consequence To Patient (2692)
Event Type  malfunction  
Event Description
It was reported that after the first biopsy sample was obtained, the slides were difficult to lock into place and the device fired on its own without being triggered.Another device was used to complete the procedure.There was no reported patient or user injury.
 
Manufacturer Narrative
The lot number for the device has not been provided; therefore, a review of the device history records could not be performed.The device has not been returned to the manufacturer for evaluation.The investigation is currently underway.
 
Manufacturer Narrative
The lot number was not reported; therefore, the device history records could not be reviewed.The investigation is inconclusive, as the sample was not returned for evaluation.Per the reported event details, the device was dry fired prior to use.The instructions for use (ifu) states, "never test the product by firing into the air.Damage may occur to the needle/cannula tip." while a definitive root cause could not be determined based upon available information, dry firing of the device may have contributed to the reported event.The current ifu (instructions for use) states.Precautions.- never test the product by firing into the air.Damage may occur to the needle / cannula tip and could result in pt and / or user injury - unusual force applied to the stylet or unusual resistance against the stylet while extended out of the supportive cannula may cause the stylet to bend at the specimen notch.A bent specimen notch may interfere with the needle function.Directions for use: energize (cock) instrument by pulling back on the top slide to withdraw the cannula and lock in place.Then pull back on the bottom slide to withdraw the stylet and lock in place.Remove protective needle sheath and yellow guard.Instrument is ready to fire when both slides are locked back; verity instrument is energized (cocked).Note: do not place fingers in front of cocking slides once instrument is energized (cocked), impeding cocking slides' movement will impact functionality.
 
Manufacturer Narrative
To ensure compliance to 21 cfr 803.50 a retrospective review of this file was conducted to determine if good faith efforts were made to obtain the required information and/or an explanation of why any required information was not provided.Multiple follow up attempts were made with the user facility to obtain any information pertaining to the patient, product, and/or procedural details (e.G.Date of the event, relevant test data, relevant history, lot #, catalog #, and concomitant product(s) or therapy) that were not previously obtained during the initial investigation.The user facility did not have any additional details to provide at this time.Also, the file was documented with a health professional as a report source, but not reported.Corrected data: reports source (added).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MAXCORE DISPOSABLE CORE BIOPSY INSTRUMENTS
Manufacturer (Section D)
BARD PERIPHERAL VASCULAR, INC.
1625 west 3rd st.
tempe AZ 85281
Manufacturer (Section G)
BARD REYNOSA S.A. DE C.V.
blvd montebello #1
parque industrial colonial
reynosa tamaulipas 88780
MX   88780
Manufacturer Contact
judith ludwig
1625 west 3rd st.
tempe, AZ 85281
4803032689
MDR Report Key4055398
MDR Text Key16563811
Report Number2020394-2014-00361
Device Sequence Number1
Product Code KNW
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K922939
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type User Facility,health professional,user f
Reporter Occupation Other
Type of Report Initial,Followup,Followup
Report Date 07/15/2014
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue NumberMC1820
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 07/15/2014
Initial Date FDA Received08/11/2014
Supplement Dates Manufacturer Received10/11/2015
10/11/2015
Supplement Dates FDA Received09/19/2014
10/29/2015
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage N
Patient Sequence Number1
-
-