Model Number HBF-140 J
Device Problems Particulates (1451); Out-Of-Box Failure (2311); Device Contamination with Chemical or Other Material (2944)
Patient Problem No Patient Involvement (2645)
Event Date 08/21/2012
Event Type  malfunction  
Event Description
On (b)(6) 2012 at (b)(6) hospital in (b)(6), it was reported that a red particle was found in the arterial filter quart hbf-140 j during priming procedure.There was no patient involvement.(b)(4).
 
Manufacturer Narrative
(b)(4).Per the final statement to complaint letter dated march 11, 2013 the foreign particulate matter originated from an abrasion of the red stopcock.Manufacturing identified the root cause and polished the molding tool to cease abrasion.A diameter reduction of the stopcock holder has been implemented to cease further red particulate matter.(b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
QUART ARTERIAL FILTER, MODEL HBF 140
Type of Device
FILTER, BLOOD, CPB, ARTERIAL LINE
Manufacturer (Section D)
MAQUET CARDIOPULMONARY AG
kehler strasse 31
rastatt, 7643 7
GM  76437
Manufacturer (Section G)
MAQUET CARDIOPULMONARY AG
kehler strasse 31
rastatt, 7643 7
GM   76437
Manufacturer Contact
tina evancho
maquet medical system, usa
45 barbour pond drive
wayne, NJ 07470
9737097265
MDR Report Key4282879
MDR Text Key5299611
Report Number8010762-2014-00461
Device Sequence Number1
Product Code DTM
Combination Product (y/n)N
Reporter Country CodeJA
PMA/PMN Number
K001787
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,User Facility,Company Representative
Reporter Occupation Other
Type of Report Initial
Report Date 08/27/2012
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date10/31/2013
Device Model NumberHBF-140 J
Device Catalogue Number70103.1617
Device Lot Number70073145
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/07/2012
Was the Report Sent to FDA? No
Distributor Facility Aware Date08/27/2012
Device Age10 MO
Event Location Hospital
Date Report to Manufacturer08/27/2012
Initial Date Manufacturer Received 08/27/2012
Initial Date FDA Received11/27/2014
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured01/10/2011
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-