MAUDE Adverse Event Report: ADVANCED STERILIZATION PRODUCTS STERRAD® CYCLESURE® 24 BIOLOGICAL INDICATOR; INDICATOR, BIOLOGICAL (FRC)

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ADVANCED STERILIZATION PRODUCTS STERRAD® CYCLESURE® 24 BIOLOGICAL INDICATOR; INDICATOR, BIOLOGICAL (FRC) Back to Search Results
Catalog Number 14324
Device Problem Appropriate Term/Code Not Available (3191)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 12/04/2014
Event Type  malfunction  
Event Description
A customer reported a positive result with a cyclesure® 24 biological indicator (bi) after a completed sterrad® 100s cycle.The bi was incubated for 24 hours.After sterilization the chemical indicator (ci) changed color correctly.The load included 16 small dental instruments, 1 eco probe, and 2 laryngoscopes.The load was partially released and used on patients before the results were confirmed.The load item released was one eco probe.There was no injury or harm associated with the issue.This event is reported to the fda since the load was partially released and used on a patient(s) before the cyclesure® 24 biological indicator (bi) results were confirmed.
 
Manufacturer Narrative
Load not recalled and suspected positive bi.
 
Manufacturer Narrative
Manufacture date 08/24/2014.Asp investigation summary: the investigation included a review of the device history record, trending of the product malfunction codes and lot number, failure mode and effects analysis, and health hazard evaluation.¿ the dhr was reviewed and the involved lot met manufacturer specifications at the time of release.No anomalies were observed that would contribute to the customer's experienced issue.¿ trending analysis for the product code of 'suspected positive bi" was reviewed from december 2013 through november 2014.The risk is categorized as "low." ¿ trending analysis for the product code of ''load not recalled" was reviewed from december 2013 through november 2014.All values are within the control limits.¿ trending analysis by lot number was reviewed from 08/24/2014 to 12/05/2014.There was no significant trend observed.¿ the fmea was reviewed and indicates the rpn associated for the failure mode is at an acceptable level.¿ the hhe was reviewed for the risk of using instruments from a load with a positive bi result which leaves a potential risk of the load not being successfully sterilized, thus could potentially transfer pathogens to patients.Each sterilization cycle is also monitored with physical parameters and chemical indicators.For the general population, the body¿s defense mechanisms make the chance for any organisms to establish into the body and cause infection to be relatively rare, especially factoring in the frequent use of prophylactic antibiotics prior to surgery.If a patient were to become infected, medical intervention would be required to resolve the infection.It is unlikely for an infection to occur; however, should it occur it could be significant for patients at greater risk.The product malfunction code of "load not recalled" was added because the customer did not successfully recall all items in the load.It is not related to a functional failure of the product.Further investigation into this issue is not required since the code is used for medwatch reporting purposes.Thirty-two (32) retains bis were subject to functional evaluation.All thirty-two bis met functional specification.Also, no damage or leakage was observed with the retains.The single cyclesure® 24 bi was returned for visual inspection.The chemical indicator disc was gold in color which indicates exposure to hydrogen peroxide.The crushed vial¿s media was yellow.No manufacturing related anomalies observed.Eleven (11) unused bis were returned for functional evaluation with two used as controls.Nine (9) bis met functional specification.Also, no damage or leakage was observed.It is unlikely the suspected positive bi was caused by a performance issue as the retains met functional specification, dhr review found no anomalies that would contribute to a positive bi result, and lot history review found no significant trend in this lot.Visual inspection revealed no manufacturing anomalies in the returned bi.Sterrad® performance is also unlikely as the cycle passed.The severity of the suspected positive bi was defined as ¿negligible.¿ tracking and trending data has not identified a trend that requires investigation.As a result, root cause evaluation will not be performed.The cyclesure® retains met functional specification.As a result, there is not an issue with product performance when used per the ifu.A customer letter has been sent addressing the ¿load not recalled.¿ the issue will continue to be tracked and trended.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
STERRAD® CYCLESURE® 24 BIOLOGICAL INDICATOR
Type of Device
INDICATOR, BIOLOGICAL (FRC)
Manufacturer (Section D)
ADVANCED STERILIZATION PRODUCTS
33 technology drive
irvine CA 92618
Manufacturer (Section G)
ADVANCED STERILIZATION PRODUCTS
33 technology drive
irvine CA 92618
Manufacturer Contact
joaquin kurz
irvine, CA 92618
MDR Report Key4371547
MDR Text Key5112040
Report Number2084725-2014-00407
Device Sequence Number1
Product Code FRC
Combination Product (y/n)N
Reporter Country CodeJA
PMA/PMN Number
K994055
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Company Representative
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 12/04/2014
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number14324
Device Lot Number23714087
Other Device ID Number14324
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/23/2015
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 03/23/2015
Initial Date FDA Received12/30/2014
Supplement Dates Manufacturer ReceivedNot provided
Supplement Dates FDA Received04/01/2015
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured08/01/2014
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-