Catalog Number 2416
Device Problem Appropriate Term/Code Not Available (3191)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 01/15/2015
Event Type  No Answer Provided  
Event Description
The customer alleges that the pressure valve did not activate.No report of patient injury or harm to a patient.
 
Manufacturer Narrative
(b)(4).A visual, functional and dimensional inspection of the product involved in the complaint could not be conducted since the product was not returned.A dhr (device history record) review could not be conducted since the lot number was not provided.A corrective action cannot be applied since it is not possible to identify the defect reported and to investigate its root cause, in order to perform a proper investigation it is necessary to evaluate the sample involved in the incident.Customer complaint cannot be confirmed due to the lack of product sample to perform a proper investigation and determine the root cause.An attempt to duplicate the failure mode was made, but at the time there is no inventory of the involved product code available at the facility and it is not being manufactured at the time.If the physical sample becomes available this complaint will be reopened.Note: a discussion with r & d engineer was conducted regarding the pressure relief valve.Per r & d, the flow rate for this set-up can be 1 to 8 lpm (ifu).The pressure relief valve is intended to activate above 8lpm in a patent set-up.Otherwise, if the set-up becomes kinked or obstructed the pressure would build up (above 8lpm) and would then activate the pressure valve.The water bottle may swell (at 1-8 lpm) without issue.From the complaint description, the pressure valve would not activate at 5-7lpm.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HUDSON CORRUGATED COMFORT FLO REMOTE TEMP POR
Type of Device
CANNULA HUMIDIFICATION SYSTEM
Manufacturer (Section D)
TELEFLEX MEDICAL
research triangle park
NC
Manufacturer (Section G)
TELEFLEX MEDICAL
parque industrial finsa
nuevo laredo, tamaulipas 8827 5
MX   88275
Manufacturer Contact
margie burton, rn
3015 carrington mill blvd
morrisville, NC 27560
9194334965
MDR Report Key4534248
MDR Text Key5356559
Report Number3004365956-2015-00062
Device Sequence Number1
Product Code BTT
Combination Product (y/n)N
Reporter Country CodeUS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional,User Facility
Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date 01/28/2015
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number2416
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 01/28/2015
Initial Date FDA Received02/20/2015
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-